Identifying key gait features in stroke patients using wearable inertial sensors and supervised and unsupervised machine learning

Stroke is a major cause of motor disability, degrading walking and quality of life. Wearable gait analysis with magneto-inertial measurement units (MIMUs) can quantify post-stroke impairments. We used machine learning to identify discriminative gait features in stroke, coupling supervised feature selection with unsupervised clustering to improve interpretability and generalizability. Eighty-five stroke patients and 97 healthy controls completed 10-Meter Walk Tests while wearing five MIMUs. Feature selection spanned spatiotemporal, symmetry, stability, and smoothness metrics. K-nearest neighbors (KNN), support vector machines (SVM), and decision trees (TREE) were trained, validated, and tested iteratively across data splits; clustering then verified discriminative ability. Sequential backward feature selection retained nine features, yielding accuracies (healthy vs. patient) of 94.1% (KNN), 96.7% (SVM), and 89.1% (TREE). SVM generalized best. Unsupervised k-medoids with cosine distance confirmed discrimination, reaching 90% accuracy with only three features: stride speed, stance-phase coefficient of variation, and medio-lateral harmonic ratio. Results indicate that gait variability, trunk smoothness, and upper-body stability robustly characterize post-stroke dysfunctions. Notably, head-movement smoothness emerged as a novel, discriminative feature. This integrated framework shows how wearable sensors plus machine learning can support clinical gait analysis and rehabilitation planning. Future work should enable real-time deployment and broaden datasets to cover more clinical scenarios.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-09
DOI
https://doi.org/10.1038/s41598-026-43666-7
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifying key gait features in stroke patients using wearable inertial sensors and supervised and unsupervised machine learning

Elena Bergamini, M. Tramontano, Giuseppe Vannozzi, Maria Gabriella Buzzi et al.
Scientific Reports
Balance, Gait, and Falls Prevention
article

Identifying key gait features in stroke patients using wearable inertial sensors and supervised and unsupervised machine learning

Elena Bergamini, M. Tramontano, Giuseppe Vannozzi, Maria Gabriella Buzzi, Paolo Brasiliano, Dante Trabassi, U. Della Croce, Valeria Belluscio, Francesca Salis, Amaranta Soledad Orejel-Bustos, Andrea Cereatti
article en

Abstract

Stroke is a major cause of motor disability, degrading walking and quality of life. Wearable gait analysis with magneto-inertial measurement units (MIMUs) can quantify post-stroke impairments. We used machine learning to identify discriminative gait features in stroke, coupling supervised feature selection with unsupervised clustering to improve interpretability and generalizability. Eighty-five stroke patients and 97 healthy controls completed 10-Meter Walk Tests while wearing five MIMUs. Feature selection spanned spatiotemporal, symmetry, stability, and smoothness metrics. K-nearest neighbors (KNN), support vector machines (SVM), and decision trees (TREE) were trained, validated, and tested iteratively across data splits; clustering then verified discriminative ability. Sequential backward feature selection retained nine features, yielding accuracies (healthy vs. patient) of 94.1% (KNN), 96.7% (SVM), and 89.1% (TREE). SVM generalized best. Unsupervised k-medoids with cosine distance confirmed discrimination, reaching 90% accuracy with only three features: stride speed, stance-phase coefficient of variation, and medio-lateral harmonic ratio. Results indicate that gait variability, trunk smoothness, and upper-body stability robustly characterize post-stroke dysfunctions. Notably, head-movement smoothness emerged as a novel, discriminative feature. This integrated framework shows how wearable sensors plus machine learning can support clinical gait analysis and rehabilitation planning. Future work should enable real-time deployment and broaden datasets to cover more clinical scenarios.

Scientific ReportsVol. 16(1)
University of Bergamo (IT), University of Sassari (IT), Politecnico di Torino (IT), Foro Italico University of Rome (IT), Azienda USL di Bologna (IT), Fondazione Santa Lucia (IT), Sapienza University of Rome (IT), University of Bologna (IT)
Reduced inequalities
Openalex Percentile: Top 31%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.