Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary

For cementless implantation of hip stems, it is very important that the original stem fits exactly into the femoral prosthesis bed previously shaped using a stem rasp. If the geometry of the stem rasp does not match the prosthesis geometry, this can result in either overstuffing or post-sintering of the original stem in relation to trial reduction with the stem rasp. Overstuffing results in leg lengthening, while subsidence of the stem results in shortening with the risk of dislocation and impingement. Trial reduction with the original stem and trial head can prevent this, but is associated with additional soft tissue trauma and a longer operating time. Three groups were prospectively randomized. Group 0 was treated with the Fitmore B stem and the conventional rasp system, Group 1 with the Optimys stem and Group 2 with the Fitmore B stem with a new, optimized rasp system via a minimally invasive posterolateral approach. Intraoperatively, the differences in leg length and offset between trial reduction with the stem rasp and the original stem were recorded using a hip navigation system. The conventional rasp system led to significant overstuffing (1.2 ± 0.5 mm, p = 0.024) with the Fitmore B stem, compared with the instruments of the Optimys stem. In contrast, the optimized rasp system with the Fitmore B stem resulted in an equally precise fit of the endoprosthesis to that achieved with Optimys. There are relevant differences in the fit of rasp and original stem between different manufacturers and system evolutions. In order to ensure reproducible comparability of the fit of the original stem to the trial rasp, it is imperative that trial rasps are optimally adapted to the stems. This is an important way to avoid trial reduction after implantation of the original stem. This study was registered in the German Clinical Trials Register (Deutsches Register Klinischer Studien) with the registration number DRKS00026749.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-03-09
DOI
https://doi.org/10.1007/s00402-026-06242-2
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary

Steffen Brodt, Philipp Knospe, Sebastian Rohe, G Wassilew et al.
Archives of Orthopaedic and Trauma Surgery
Orthopaedic implants and arthroplasty
article

Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary

Steffen Brodt, Philipp Knospe, Sebastian Rohe, G Wassilew, Georg Matziolis, Pablo Sanz-Ruiz
article en

Abstract

For cementless implantation of hip stems, it is very important that the original stem fits exactly into the femoral prosthesis bed previously shaped using a stem rasp. If the geometry of the stem rasp does not match the prosthesis geometry, this can result in either overstuffing or post-sintering of the original stem in relation to trial reduction with the stem rasp. Overstuffing results in leg lengthening, while subsidence of the stem results in shortening with the risk of dislocation and impingement. Trial reduction with the original stem and trial head can prevent this, but is associated with additional soft tissue trauma and a longer operating time. Three groups were prospectively randomized. Group 0 was treated with the Fitmore B stem and the conventional rasp system, Group 1 with the Optimys stem and Group 2 with the Fitmore B stem with a new, optimized rasp system via a minimally invasive posterolateral approach. Intraoperatively, the differences in leg length and offset between trial reduction with the stem rasp and the original stem were recorded using a hip navigation system. The conventional rasp system led to significant overstuffing (1.2 ± 0.5 mm, p = 0.024) with the Fitmore B stem, compared with the instruments of the Optimys stem. In contrast, the optimized rasp system with the Fitmore B stem resulted in an equally precise fit of the endoprosthesis to that achieved with Optimys. There are relevant differences in the fit of rasp and original stem between different manufacturers and system evolutions. In order to ensure reproducible comparability of the fit of the original stem to the trial rasp, it is imperative that trial rasps are optimally adapted to the stems. This is an important way to avoid trial reduction after implantation of the original stem. This study was registered in the German Clinical Trials Register (Deutsches Register Klinischer Studien) with the registration number DRKS00026749.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
Universitätsmedizin Greifswald (DE), Hospital General Universitario Gregorio Marañón (ES), Waldkrankenhaus Rudolf Elle (DE)
Openalex Percentile: Top 29%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.