Conundrums of Localized Surface Plasmon Resonance Biosensors

Localized surface plasmon resonance (LSPR) biosensing offers label-free, real-time detection of biomolecular interactions with high sensitivity and compact instrumentation. However, despite widespread use, several persistent and poorly understood phenomena limit the reproducibility, quantitation, and interpretability of LSPR signals. This perspective examines six recurring "conundrums" in LSPR biosensing, with a focus on their physical origins, experimental manifestations, and current approaches to mitigation. I review puzzling cases where analyte binding induces either red or blueshifts of the plasmon resonance; the difficulty of isolating the surface-confined signal from bulk refractive-index drift in microfluidics; the finite decay length of the plasmon field and the resulting saturation for thick or inhomogeneous layers; environmental cross-sensitivities to temperature, pH, and ionic strength; run-to-run variability in nanostructure fabrication; and spectral congestion in multiplexed measurements. For each, I discuss the state of understanding, identify open questions, and outline strategies from advanced optical readouts to algorithmic baseline correction that could enable truly quantitative, drift-immune, and reproducible LSPR biosensing.

Authors

Institutions

Publication Details

Journal
Small
Published
2026-03-09
DOI
https://doi.org/10.1002/smll.202513520
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conundrums of Localized Surface Plasmon Resonance Biosensors

Nikhil Bhalla
Small
Monoclonal and Polyclonal Antibodies Research
article

Conundrums of Localized Surface Plasmon Resonance Biosensors

Nikhil Bhalla
article en

Abstract

Localized surface plasmon resonance (LSPR) biosensing offers label-free, real-time detection of biomolecular interactions with high sensitivity and compact instrumentation. However, despite widespread use, several persistent and poorly understood phenomena limit the reproducibility, quantitation, and interpretability of LSPR signals. This perspective examines six recurring "conundrums" in LSPR biosensing, with a focus on their physical origins, experimental manifestations, and current approaches to mitigation. I review puzzling cases where analyte binding induces either red or blueshifts of the plasmon resonance; the difficulty of isolating the surface-confined signal from bulk refractive-index drift in microfluidics; the finite decay length of the plasmon field and the resulting saturation for thick or inhomogeneous layers; environmental cross-sensitivities to temperature, pH, and ionic strength; run-to-run variability in nanostructure fabrication; and spectral congestion in multiplexed measurements. For each, I discuss the state of understanding, identify open questions, and outline strategies from advanced optical readouts to algorithmic baseline correction that could enable truly quantitative, drift-immune, and reproducible LSPR biosensing.

Small
University of Ulster (GB)
Openalex Percentile: Top 30%
Monoclonal and Polyclonal Antibodies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.