Head Tilt as a Technique to Reduce Contralateral Arch Artifacts in Small Field of View Cone Beam Computed Tomography Imaging

Background/Objectives: Cone beam computed tomography (CBCT) is vital in endodontics but suffers from beam-hardening artifacts caused by metallic restorations, which can obscure diagnostic details. This study evaluated a novel patient positioning protocol—a controlled head tilt—designed to mitigate these artifacts by moving contralateral metallic structures outside the primary X-ray path in small field of view (FoV) CBCTs. Methods: Using a skull phantom with metallic restorations CBCT scans were acquired in three positions: standard alignment, a 12° tilt toward the region of interest (ROI), and a 12° tilt to the opposite side. Fifty experienced dentists, blinded to the protocol, subjectively compared image quality and artifact severity between the tilted and reference images. Results: The tilt away from the ROI was rated as providing better image quality significantly more often than the tilt towards the side of the ROI (442 of 585 non-tied comparisons; p < 0.001). A complementary rater-clustered GEE analysis adjusted for slide confirmed higher odds of “better” ratings under head tilt away from the ROI for image quality (OR = 4.16, 95% CI 3.12–5.56) and artefacts (OR = 2.87, 95% CI 1.93–4.26). An individual head tilt significantly improves subjective small-FoV CBCT image quality, most evidently in the longitudinal plane, by reducing artifact interference from contralateral metals, and should be considered a practical strategy for clinical use, and may serve as a practical chairside strategy, pending clinical validation.

Authors

Institutions

Publication Details

Journal
Oral
Published
2026-03-09
DOI
https://doi.org/10.3390/oral6020029
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Head Tilt as a Technique to Reduce Contralateral Arch Artifacts in Small Field of View Cone Beam Computed Tomography Imaging

Sebastian Fitzek, Dritan Turhani, Marius Meier, Jörg Philipp Tchorz et al.
Oral
Dental Radiography and Imaging
article

Head Tilt as a Technique to Reduce Contralateral Arch Artifacts in Small Field of View Cone Beam Computed Tomography Imaging

Sebastian Fitzek, Dritan Turhani, Marius Meier, Jörg Philipp Tchorz, Dominik Niklas Elvers, Philipp Johann Poxleitner
article en

Abstract

Background/Objectives: Cone beam computed tomography (CBCT) is vital in endodontics but suffers from beam-hardening artifacts caused by metallic restorations, which can obscure diagnostic details. This study evaluated a novel patient positioning protocol—a controlled head tilt—designed to mitigate these artifacts by moving contralateral metallic structures outside the primary X-ray path in small field of view (FoV) CBCTs. Methods: Using a skull phantom with metallic restorations CBCT scans were acquired in three positions: standard alignment, a 12° tilt toward the region of interest (ROI), and a 12° tilt to the opposite side. Fifty experienced dentists, blinded to the protocol, subjectively compared image quality and artifact severity between the tilted and reference images. Results: The tilt away from the ROI was rated as providing better image quality significantly more often than the tilt towards the side of the ROI (442 of 585 non-tied comparisons; p < 0.001). A complementary rater-clustered GEE analysis adjusted for slide confirmed higher odds of “better” ratings under head tilt away from the ROI for image quality (OR = 4.16, 95% CI 3.12–5.56) and artefacts (OR = 2.87, 95% CI 1.93–4.26). An individual head tilt significantly improves subjective small-FoV CBCT image quality, most evidently in the longitudinal plane, by reducing artifact interference from contralateral metals, and should be considered a practical strategy for clinical use, and may serve as a practical chairside strategy, pending clinical validation.

OralVol. 6(2)
Danube Private University (AT), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 27%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Head Tilt as a Technique to Reduce Contralateral Arch Artifacts in Small Field of View Cone Beam Computed Tomography Imaging — Sebastian Fitzek, Dritan Turhani, et al. · Oral (2026) | TGRS Research Map | TGRS