Exploratory clinical trial on the acoustic variability index for predicting fluid responsiveness during hepatectomy

The acoustic variability index (AVI), derived from continuous phonocardiographic analysis of heart sounds via an esophageal stethoscope, is a novel minimally invasive method for intraoperative hemodynamic monitoring. We evaluated the ability of AVI to predict fluid responsiveness in patients undergoing hepatectomy and compared its performance with that of the conventional indices. Forty adult patients who underwent hepatectomy were enrolled in this prospective, single-center observational study. After major surgical resection and stabilization, a 500 mL crystalloid fluid challenge was administered. Hemodynamic parameters including AVI, central venous pressure (CVP), stroke volume variation (SVV), and pulse pressure variation (PPV) were recorded before and after volume expansion. Patients with ≥ 10% increase in cardiac output (CO) were defined as responders. Thirty-seven patients were included in the final analysis, of which 12 (32.4%) were classified as responders. After fluid loading, responders showed a significant decrease in AVI (11.4% ± 2.5% to 7.8% ± 2.9%, p = 0.004), while non-responders showed no significant change (7.1% ± 3.2% to 6.3% ± 3.0%, p = 0.356). AVI demonstrated predictive performance comparable to SVV and PPV, with an optimal cutoff of > 9.8% and an area under the receiver operating characteristic curve of 0.873 (95% CI: 0.743–0.967). Real-time intraoperative monitoring of the AVI shows potential as a predictor for fluid responsiveness in patients undergoing hepatectomy. AVI offers a promising, minimally invasive approach for guiding fluid therapy. Further research is warranted to validate its utility in broader surgical populations.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2026-03-09
DOI
https://doi.org/10.1007/s10877-026-01427-x
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploratory clinical trial on the acoustic variability index for predicting fluid responsiveness during hepatectomy

Jun‐Gol Song, Baehun Moon, G. C. Park, Sung‐Hoon Kim et al.
Journal of Clinical Monitoring and Computing
Hemodynamic Monitoring and Therapy
article

Exploratory clinical trial on the acoustic variability index for predicting fluid responsiveness during hepatectomy

Jun‐Gol Song, Baehun Moon, G. C. Park, Sung‐Hoon Kim, James S Park, Kyu-Min Kang, Hye-Mee Kwon, In-Gu Jun, Hyun-Seok Kim, Woo-Young Seo, Chang-Hoe Heo, Gyu-Sam Hwang
article en

Abstract

The acoustic variability index (AVI), derived from continuous phonocardiographic analysis of heart sounds via an esophageal stethoscope, is a novel minimally invasive method for intraoperative hemodynamic monitoring. We evaluated the ability of AVI to predict fluid responsiveness in patients undergoing hepatectomy and compared its performance with that of the conventional indices. Forty adult patients who underwent hepatectomy were enrolled in this prospective, single-center observational study. After major surgical resection and stabilization, a 500 mL crystalloid fluid challenge was administered. Hemodynamic parameters including AVI, central venous pressure (CVP), stroke volume variation (SVV), and pulse pressure variation (PPV) were recorded before and after volume expansion. Patients with ≥ 10% increase in cardiac output (CO) were defined as responders. Thirty-seven patients were included in the final analysis, of which 12 (32.4%) were classified as responders. After fluid loading, responders showed a significant decrease in AVI (11.4% ± 2.5% to 7.8% ± 2.9%, p = 0.004), while non-responders showed no significant change (7.1% ± 3.2% to 6.3% ± 3.0%, p = 0.356). AVI demonstrated predictive performance comparable to SVV and PPV, with an optimal cutoff of > 9.8% and an area under the receiver operating characteristic curve of 0.873 (95% CI: 0.743–0.967). Real-time intraoperative monitoring of the AVI shows potential as a predictor for fluid responsiveness in patients undergoing hepatectomy. AVI offers a promising, minimally invasive approach for guiding fluid therapy. Further research is warranted to validate its utility in broader surgical populations.

Journal of Clinical Monitoring and Computing
Ulsan College (KR), Asan Medical Center (KR), University of Ulsan (KR), AI Signal Research (United States) (US), Hyundai Engineering (South Korea) (KR)
Good health and well-being
Openalex Percentile: Top 29%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies