Piezoelectric paint-based force sensor for hand rehabilitation

A novel hand rehabilitation device for spinal cord injury patients has been designed with piezoelectric paint-based cantiléver beam force sensors. The piezoelectric paint is made of piezoelectric powder homogeneously distributed in a polymer binder (water-based acrylic). The proposed device is constituted by 16 cantilever beam force sensors activated by push-buttons which allows us to measure the applied forcé with the fingers of the hand helping in the recovery of the patient. The sensors were calibrated, obtaining a linear relationship between the electric signal and the applied forcé and a sensitivity about 8 V/N. The proposed method has been designed to improve the hand-eye coordination when the patient applies a controlled force with the fingers. Two exercises were proposed for tracking different force profiles and demonstrate the usefulnes of the device.

Authors

Publication Details

Published
2026-03-09
DOI
https://doi.org/10.31428/10317/13809
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Piezoelectric paint-based force sensor for hand rehabilitation

Juárez Pérez Sergio, Payo Gutiérrez Ismael, Reyes Guzmán Ana de los, López Dolado Elisa et al.
Advanced Sensor and Energy Harvesting Materials
article

Piezoelectric paint-based force sensor for hand rehabilitation

Juárez Pérez Sergio, Payo Gutiérrez Ismael, Reyes Guzmán Ana de los, López Dolado Elisa, Fernández Almenar Javier, Rodríguez Rosa David
article en

Abstract

A novel hand rehabilitation device for spinal cord injury patients has been designed with piezoelectric paint-based cantiléver beam force sensors. The piezoelectric paint is made of piezoelectric powder homogeneously distributed in a polymer binder (water-based acrylic). The proposed device is constituted by 16 cantilever beam force sensors activated by push-buttons which allows us to measure the applied forcé with the fingers of the hand helping in the recovery of the patient. The sensors were calibrated, obtaining a linear relationship between the electric signal and the applied forcé and a sensitivity about 8 V/N. The proposed method has been designed to improve the hand-eye coordination when the patient applies a controlled force with the fingers. Two exercises were proposed for tracking different force profiles and demonstrate the usefulnes of the device.

Good health and well-being
Openalex Percentile: Top 30%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.