Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell

Oxygen permeability (Dk) is a key parameter for evaluating the ability of contact lenses to supply oxygen to the cornea. Although the polarographic method has been standardized as a reference technique for Dk measurement, conventional polarographic electrode cells are limited to a narrow central measurement area of approximately 4 mm in diameter, which may not adequately represent oxygen transport under actual wearing conditions. In this study, a modified polarographic electrode cell enabling wide-field oxygen permeability measurement over an expanded central area with a diameter of 11 mm was developed and evaluated under ISO 18369 measurement conditions. The performance of the proposed system was evaluated by comparing its accuracy, repeatability, and relative error with those of a conventional polarographic electrode cell using plano hydrogel contact lens samples with different uniform thicknesses. The Dk values obtained using the modified measurement cell did not show a statistically significant difference compared to those measured with the conventional measurement cell (t = 2.682, <i>p</i> = 0.055), and the relative error between the two systems was 1.93%, meeting the ISO acceptance criteria for the development of a new testing method. These results demonstrate that wide-field Dk measurement can be achieved without compromising reliability, providing a more representative and ISO-compliant approach for contact lens oxygen permeability evaluation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-03-09
DOI
https://doi.org/10.3390/s26051725
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell

Wen-Hong Tong, Jaeyeon Pyo, J. Liu, Seung-Jin Oh et al.
Sensors
Corneal surgery and disorders
article

Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell

Wen-Hong Tong, Jaeyeon Pyo, J. Liu, Seung-Jin Oh, Jae-Young Jang, Ki-Choong Mah
article en

Abstract

Oxygen permeability (Dk) is a key parameter for evaluating the ability of contact lenses to supply oxygen to the cornea. Although the polarographic method has been standardized as a reference technique for Dk measurement, conventional polarographic electrode cells are limited to a narrow central measurement area of approximately 4 mm in diameter, which may not adequately represent oxygen transport under actual wearing conditions. In this study, a modified polarographic electrode cell enabling wide-field oxygen permeability measurement over an expanded central area with a diameter of 11 mm was developed and evaluated under ISO 18369 measurement conditions. The performance of the proposed system was evaluated by comparing its accuracy, repeatability, and relative error with those of a conventional polarographic electrode cell using plano hydrogel contact lens samples with different uniform thicknesses. The Dk values obtained using the modified measurement cell did not show a statistically significant difference compared to those measured with the conventional measurement cell (t = 2.682, <i>p</i> = 0.055), and the relative error between the two systems was 1.93%, meeting the ISO acceptance criteria for the development of a new testing method. These results demonstrate that wide-field Dk measurement can be achieved without compromising reliability, providing a more representative and ISO-compliant approach for contact lens oxygen permeability evaluation.

SensorsVol. 26(5)
World Vision (US), Eulji University (KR), Korea Institute of Civil Engineering and Building Technology (KR), Semyung University (KR), Jinhua University of Vocational Technology (CN), CHA University Gangnam Medical Center (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 30%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.