Influence of the screw-home mechanism on TT-TG distance: a 3D kinematic simulation study

The axial distance between the tibial tuberosity and the trochlear groove (TT-TG) is a significant parameter in the preoperative analysis of patellofemoral instability. Discrepancies in TT-TG measurements between imaging modalities are largely attributed to differences in knee flexion and the associated tibial rotation (screw-home mechanism). However, the quantitative impact of the screw-home mechanism and its inter-individual variability on TT-TG measurement remains incompletely characterized. The aim of this study was to measure and evaluate the influence of the screw-home mechanism during knee flexion on the TT-TG distance. 56 computed tomography (CT) scans were obtained and segmented into surface models. Anatomic landmarks were defined to determine the TT-TG. Kinematic simulations of knee flexion (0–30° in 10° increments) were performed. Concurrently, various combined screw-home mechanisms were performed in 5° increments (0–20°) for each model. Data analysis involved the paired samples Friedman test with post-hoc Wilcoxon signed-rank tests (p < 0.05). Flexion and internal tibial rotation led to significant changes in TT-TG values (p < 0.001). Post-hoc analyses showed that all pairwise comparisons within a degree of flexion were statistically significant at different rotation angles. Knee flexion resulted in minimal changes in TT-TG distance, whereas the additional screw-home mechanism caused significant deviations depending on the degree of flexion and rotation, ranging from -1.5 mm (± 0.3) to − 11.0 mm (± 1.1). Once the rotation was complete, further flexion increased the TT-TG distance. The TT-TG distance is significantly influenced by the screw-home mechanism. Standardizing the TT-TG assessment at 30° of flexion minimizes rotational variability, potentially improving diagnostic consistency. However, in vivo validation is required before clinical implementation.

Authors

Institutions

Publication Details

Journal
European Journal of Orthopaedic Surgery & Traumatology
Published
2026-03-09
DOI
https://doi.org/10.1007/s00590-026-04708-y
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the screw-home mechanism on TT-TG distance: a 3D kinematic simulation study

Maximilian Jörgens, Julius Watrinet, Julian Fürmetz, Boris Michael Holzapfel et al.
European Journal of Orthopaedic Surgery & Traumatology
Lower Extremity Biomechanics and Pathologies
article

Influence of the screw-home mechanism on TT-TG distance: a 3D kinematic simulation study

Maximilian Jörgens, Julius Watrinet, Julian Fürmetz, Boris Michael Holzapfel, Wolfgang Böcker, Markus Bormann, Sebastian Siebenlist
article en

Abstract

The axial distance between the tibial tuberosity and the trochlear groove (TT-TG) is a significant parameter in the preoperative analysis of patellofemoral instability. Discrepancies in TT-TG measurements between imaging modalities are largely attributed to differences in knee flexion and the associated tibial rotation (screw-home mechanism). However, the quantitative impact of the screw-home mechanism and its inter-individual variability on TT-TG measurement remains incompletely characterized. The aim of this study was to measure and evaluate the influence of the screw-home mechanism during knee flexion on the TT-TG distance. 56 computed tomography (CT) scans were obtained and segmented into surface models. Anatomic landmarks were defined to determine the TT-TG. Kinematic simulations of knee flexion (0–30° in 10° increments) were performed. Concurrently, various combined screw-home mechanisms were performed in 5° increments (0–20°) for each model. Data analysis involved the paired samples Friedman test with post-hoc Wilcoxon signed-rank tests (p < 0.05). Flexion and internal tibial rotation led to significant changes in TT-TG values (p < 0.001). Post-hoc analyses showed that all pairwise comparisons within a degree of flexion were statistically significant at different rotation angles. Knee flexion resulted in minimal changes in TT-TG distance, whereas the additional screw-home mechanism caused significant deviations depending on the degree of flexion and rotation, ranging from -1.5 mm (± 0.3) to − 11.0 mm (± 1.1). Once the rotation was complete, further flexion increased the TT-TG distance. The TT-TG distance is significantly influenced by the screw-home mechanism. Standardizing the TT-TG assessment at 30° of flexion minimizes rotational variability, potentially improving diagnostic consistency. However, in vivo validation is required before clinical implementation.

European Journal of Orthopaedic Surgery & TraumatologyVol. 36(1)
LMU Klinikum (DE), Berufsgenossenschaftliche Unfallklinik Murnau (DE), Garmisch-Partenkirchen Medical Center (DE), Technical University of Munich (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 30%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.