Replicating Expert Bone Measurements Automatically: A Case Study with Femoral Allografts

Precise morphological assessment of bone allografts is essential for successful graft-recipient matching in tissue banking. Manual measurement protocols, while standard, are labor-intensive, time-consuming, and prone to inter- and intra-observer variability. To overcome these limitations, this work presents an automated system integrated into the BeST-Graft Viewer for performing femoral allograft measurements. The proposed method replicates expert measurement strategies by defining anatomical search zones and reference planes directly within the 3D model of the femur. Reference points are automatically detected based on geometric conditions, and the corresponding anatomical parameters are computed using predefined formulas. The system was validated against manual measurements performed by three experienced experts, using 3D reconstructions of femoral grafts. Manual measurements demonstrated excellent intra- and interrater reliability, with ICC values mostly above 0.98 and all exceeding 0.89, validating their use as a reference standard. The automated system showed near-perfect agreement with the expert average (Pearson's r = 0.99997), with no significant systematic differences observed. Moreover, the automated process required less than 15 seconds per femur with a single user interaction, in contrast to the several minutes and multiple steps needed for manual annotation. The automated measurement system provides accurate, reproducible, and highly efficient assessment of femoral allografts. It eliminates user variability and reduces measurement time by orders of magnitude. The method offers a reliable and scalable solution for integration into routine clinical workflows, and has potential for extension to other anatomical graft types.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-03-09
DOI
https://doi.org/10.1007/s10278-026-01850-1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Replicating Expert Bone Measurements Automatically: A Case Study with Femoral Allografts

Adrià Julià i Juanola, Pau Xiberta, Màrius Vila, Oscar Fariñas et al.
Journal of Imaging Informatics in Medicine
Orthopaedic implants and arthroplasty
article

Replicating Expert Bone Measurements Automatically: A Case Study with Femoral Allografts

Adrià Julià i Juanola, Pau Xiberta, Màrius Vila, Oscar Fariñas, Marc Ruiz, Raquel Bermudo, Imma Boada
article en

Abstract

Precise morphological assessment of bone allografts is essential for successful graft-recipient matching in tissue banking. Manual measurement protocols, while standard, are labor-intensive, time-consuming, and prone to inter- and intra-observer variability. To overcome these limitations, this work presents an automated system integrated into the BeST-Graft Viewer for performing femoral allograft measurements. The proposed method replicates expert measurement strategies by defining anatomical search zones and reference planes directly within the 3D model of the femur. Reference points are automatically detected based on geometric conditions, and the corresponding anatomical parameters are computed using predefined formulas. The system was validated against manual measurements performed by three experienced experts, using 3D reconstructions of femoral grafts. Manual measurements demonstrated excellent intra- and interrater reliability, with ICC values mostly above 0.98 and all exceeding 0.89, validating their use as a reference standard. The automated system showed near-perfect agreement with the expert average (Pearson's r = 0.99997), with no significant systematic differences observed. Moreover, the automated process required less than 15 seconds per femur with a single user interaction, in contrast to the several minutes and multiple steps needed for manual annotation. The automated measurement system provides accurate, reproducible, and highly efficient assessment of femoral allografts. It eliminates user variability and reduces measurement time by orders of magnitude. The method offers a reliable and scalable solution for integration into routine clinical workflows, and has potential for extension to other anatomical graft types.

Journal of Imaging Informatics in Medicine
Universitat de Girona (ES), Vall d'Hebron Institut de Recerca (ES), Biomedical Research Institute (US), Banc de Sang i Teixits (ES)
Decent work and economic growth
Openalex Percentile: Top 30%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.