Monitoring and analysis of existing post-tensioned bridge using FBG sensors

Administrators today face the challenge of assessing existing prestressed bridges. In Europe, many of these structures were designed and constructed in the post-war era. Unfortunately, early prestressed bridges are often associated with conceptual errors, such as inadequate protection of the prestressing steel. As a result, it is essential to verify the structural response while considering all factors that may negatively impact the residual prestressing value. This paper presents a case study involving a static load test monitored by modern fibre Bragg grating (FBG) sensors. The analysis focused on a three-span, double-cell box girder, post-tensioned bridge built in 1966. A diagnostic survey and static load test were conducted during rehabilitation after several prestressing wires were damaged. The primary goal was to study the structure’s behaviour under static load from 30-ton heavy vehicles. In this context, in-situ measurements were used to simulate the heavy pavement mechanisms associated with construction activities. The observed responses included deflections, strains, and temperature. The test results showed good agreement with the numerical analysis, indicating a linear response of the structure, with no additional wire breakage observed. Notably, thermal loads had a greater impact than static loads during the test. Long-term monitoring revealed that strain variations throughout the day fluctuated by approximately ±20–25 με, while the external load induced a maximum strain of 12 με. In conclusion, it was recommended to allow the bridge to operate under real-time monitoring, enabling the mechanisms to function effectively.

Authors

Institutions

Publication Details

Journal
Cogent Engineering
Published
2026-03-07
DOI
https://doi.org/10.1080/23311916.2026.2639837
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring and analysis of existing post-tensioned bridge using FBG sensors

Radim Šifta, Martin Moravčík, Jakub Kralovanec
Cogent Engineering
Advanced Fiber Optic Sensors
article

Monitoring and analysis of existing post-tensioned bridge using FBG sensors

Radim Šifta, Martin Moravčík, Jakub Kralovanec
article en

Abstract

Administrators today face the challenge of assessing existing prestressed bridges. In Europe, many of these structures were designed and constructed in the post-war era. Unfortunately, early prestressed bridges are often associated with conceptual errors, such as inadequate protection of the prestressing steel. As a result, it is essential to verify the structural response while considering all factors that may negatively impact the residual prestressing value. This paper presents a case study involving a static load test monitored by modern fibre Bragg grating (FBG) sensors. The analysis focused on a three-span, double-cell box girder, post-tensioned bridge built in 1966. A diagnostic survey and static load test were conducted during rehabilitation after several prestressing wires were damaged. The primary goal was to study the structure’s behaviour under static load from 30-ton heavy vehicles. In this context, in-situ measurements were used to simulate the heavy pavement mechanisms associated with construction activities. The observed responses included deflections, strains, and temperature. The test results showed good agreement with the numerical analysis, indicating a linear response of the structure, with no additional wire breakage observed. Notably, thermal loads had a greater impact than static loads during the test. Long-term monitoring revealed that strain variations throughout the day fluctuated by approximately ±20–25 με, while the external load induced a maximum strain of 12 με. In conclusion, it was recommended to allow the bridge to operate under real-time monitoring, enabling the mechanisms to function effectively.

Cogent EngineeringVol. 13(1)
University of Žilina (SK), Network Group (Czechia) (CZ)
Openalex Percentile: Top 30%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.