Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer

Abstract Ensuring frequency stability in interconnected power systems is challenging due to continuous load variations and fluctuations in tie-line power. This study focuses on designing and optimizing controllers for Automatic Generation Control (AGC) of a two-area power system to achieve zero-frequency deviation under dynamic load conditions. Five different controllers—PID (Proportional-Integral-Derivative), PIDn, FOPID (Fractional Order PID), TID (Tilt-Integral-Derivative), and PIDA—were tested. Their parameters were optimized using seven advanced metaheuristic algorithms: Artificial Rabbit Optimization, Chernobyl Disaster Optimizer (CDO), Modified Chernobyl Disaster Optimizer (mCDO), Golden Jackal Optimization, Honey Badger Algorithm, Mont-Flame Optimization, and Spider Wasp Optimizer. A total of 35 simulation studies were conducted, and performance was evaluated using the Integral of Time-Weighted Absolute Error (ITAE) metric Among the tested controllers, the FOPID-mCDO combination achieved the lowest ITAE value (0.320684), a settling time of 3.6 s, and minimal overshoot (0.0083 Hz) and undershoot (− 0.1480 Hz). Compared to conventional PID controllers, this configuration reduced settling time by 10% and improved frequency stability under dynamic load variations. The proposed mCDO algorithm, which integrates neighborhood–global and wandering search strategies to enhance the exploration–exploitation balance of the original CDO, outperformed the standard CDO by enabling faster convergence and more precise parameter tuning. The findings indicate that the FOPID-mCDO combination is a promising approach for automatic generation control in multi-area power systems.

Authors

Institutions

Publication Details

Journal
The Journal of Supercomputing
Published
2026-03-07
DOI
https://doi.org/10.1007/s11227-026-08348-1
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer

Anas Bouaouda, Fatma A. Hashim, Onur Özdal Mengi, Aykut Fatih Güven et al.
The Journal of Supercomputing
Frequency Control in Power Systems
article

Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer

Anas Bouaouda, Fatma A. Hashim, Onur Özdal Mengi, Aykut Fatih Güven, Salah Kamel
article en

Abstract

Abstract Ensuring frequency stability in interconnected power systems is challenging due to continuous load variations and fluctuations in tie-line power. This study focuses on designing and optimizing controllers for Automatic Generation Control (AGC) of a two-area power system to achieve zero-frequency deviation under dynamic load conditions. Five different controllers—PID (Proportional-Integral-Derivative), PIDn, FOPID (Fractional Order PID), TID (Tilt-Integral-Derivative), and PIDA—were tested. Their parameters were optimized using seven advanced metaheuristic algorithms: Artificial Rabbit Optimization, Chernobyl Disaster Optimizer (CDO), Modified Chernobyl Disaster Optimizer (mCDO), Golden Jackal Optimization, Honey Badger Algorithm, Mont-Flame Optimization, and Spider Wasp Optimizer. A total of 35 simulation studies were conducted, and performance was evaluated using the Integral of Time-Weighted Absolute Error (ITAE) metric Among the tested controllers, the FOPID-mCDO combination achieved the lowest ITAE value (0.320684), a settling time of 3.6 s, and minimal overshoot (0.0083 Hz) and undershoot (− 0.1480 Hz). Compared to conventional PID controllers, this configuration reduced settling time by 10% and improved frequency stability under dynamic load variations. The proposed mCDO algorithm, which integrates neighborhood–global and wandering search strategies to enhance the exploration–exploitation balance of the original CDO, outperformed the standard CDO by enabling faster convergence and more precise parameter tuning. The findings indicate that the FOPID-mCDO combination is a promising approach for automatic generation control in multi-area power systems.

The Journal of SupercomputingVol. 82(4)
Giresun University (TR), Yalova University (TR), Institut de Recerca en Energia de Catalunya (ES), Helwan University (EG), Aswan University (EG)
Climate action
Openalex Percentile: Top 31%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.