Liquid thickness estimation in transmission electron microscopy

Transmission electron microscopy has become a valuable tool for time-resolved characterization of nano-scale materials during exposure to liquid environments. As the imaging resolution and contrast depends on liquid thickness, measurements and control of the liquid phase are of critical importance. While the log-ratio method in electron energy-loss spectroscopy (EELS) has been demonstrated for estimating the thickness of thin liquid layers, this method becomes unreliable for liquid layers, with log-ratio measures larger than 4. Herein, we demonstrate that the energy position of the multiple scattering peak can be calibrated to be used as an alternative thickness measure of thicker samples in both broad-beam and focused-beam illumination conditions. With this approach it is shown that in addition to unavoidable window bulging of the silicon nitride window membranes, the silicon chips can also bulge when clamped in the liquid holder which gives rise to additional liquid thickness and means to suppress this unwanted effect are demonstrated.

Authors

Institutions

Publication Details

Journal
Ultramicroscopy
Published
2026-03-07
DOI
https://doi.org/10.1016/j.ultramic.2026.114350
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Liquid thickness estimation in transmission electron microscopy

Lau Morten Kaas, Christian Danvad Damsgaard, Raquel Aymerich‐Armengol, Peter C. K. Vesborg et al.
Ultramicroscopy
Advanced Electron Microscopy Techniques and Applications
article

Liquid thickness estimation in transmission electron microscopy

Lau Morten Kaas, Christian Danvad Damsgaard, Raquel Aymerich‐Armengol, Peter C. K. Vesborg, Stig Helveg, Jakob Kibsgaard, Daan Hein Alsem
article en

Abstract

Transmission electron microscopy has become a valuable tool for time-resolved characterization of nano-scale materials during exposure to liquid environments. As the imaging resolution and contrast depends on liquid thickness, measurements and control of the liquid phase are of critical importance. While the log-ratio method in electron energy-loss spectroscopy (EELS) has been demonstrated for estimating the thickness of thin liquid layers, this method becomes unreliable for liquid layers, with log-ratio measures larger than 4. Herein, we demonstrate that the energy position of the multiple scattering peak can be calibrated to be used as an alternative thickness measure of thicker samples in both broad-beam and focused-beam illumination conditions. With this approach it is shown that in addition to unavoidable window bulging of the silicon nitride window membranes, the silicon chips can also bulge when clamped in the liquid holder which gives rise to additional liquid thickness and means to suppress this unwanted effect are demonstrated.

UltramicroscopyVol. 283
Hummingbird Scientific (United States) (US), Technical University of Denmark (DK)
Affordable and clean energy
Openalex Percentile: Top 27%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Liquid thickness estimation in transmission electron microscopy — Lau Morten Kaas, Christian Danvad Damsgaard, et al. · Ultramicroscopy (2026) | TGRS Research Map | TGRS