Empirical investigation on the thermal behaviour of photovoltaic modules under fault conditions and localised heating

• PV module temperature increased by up to 2.8°C under open-circuit conditions. • PV faults warmed adjacent modules by + 6.8°C and near-surface air (1 m) by + 0.56°C. • Results highlight the impact of electrical faults on module and air temperatures. Undetected electrical faults in photovoltaic (PV) systems can alter module temperatures and influence rooftop thermal environments, yet empirical evidence under real operating conditions remains limited. Unlike prior studies that rely on laboratory experiments, simulations, or aggregated string-level data, this study presents a full-scale, in-situ, module-level investigation of thermal behaviour across normal (ON), open-circuit (OC), and short-circuit (SC) states, integrating surface and air temperature measurements to assess module-level and microclimatic responses. Among the tested conditions, the transition from ON to OC exhibited the most notable and statistically significant changes. Under clear-sky conditions, OC modules were +2.1°C to +2.8°C warmer than during normal operation, while the SC state produced only minor additional warming (+1.4°C) in one module type. Beyond individual surface heating, the ON → OC transition caused a measurable adjacency effect, increasing the temperature of neighbouring modules by +6.8°C, based on irradiance-normalised estimates at ∼0.95 kW/m 2 , between 14:00 h and 15:00 h. In parallel, near-surface air at 1 m warmed by +0.56°C, reinforcing the understanding that module-level heating under OC conditions can extend into the surrounding rooftop microclimate. Material characteristics further shaped these responses, with higher-efficiency, wider-bandgap modules exhibiting greater thermal stability. Collectively, the findings provide empirical evidence that PV systems function not only as renewable energy sources but also as active thermal elements influencing rooftop microclimates across operating states. These results extend PV fault research beyond purely electrical diagnostics, introducing an integrated rooftop energy-thermal perspective directly relevant to system design, performance monitoring, and urban microclimate assessment in dense tropical environments.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-03-07
DOI
https://doi.org/10.1016/j.solener.2026.114492
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Empirical investigation on the thermal behaviour of photovoltaic modules under fault conditions and localised heating

Carlos Rodriguez-Gallegos, Stephen En Rong Tay, Shi An Ting
Solar Energy
Photovoltaic System Optimization Techniques
article

Empirical investigation on the thermal behaviour of photovoltaic modules under fault conditions and localised heating

Carlos Rodriguez-Gallegos, Stephen En Rong Tay, Shi An Ting
article en

Abstract

• PV module temperature increased by up to 2.8°C under open-circuit conditions. • PV faults warmed adjacent modules by + 6.8°C and near-surface air (1 m) by + 0.56°C. • Results highlight the impact of electrical faults on module and air temperatures. Undetected electrical faults in photovoltaic (PV) systems can alter module temperatures and influence rooftop thermal environments, yet empirical evidence under real operating conditions remains limited. Unlike prior studies that rely on laboratory experiments, simulations, or aggregated string-level data, this study presents a full-scale, in-situ, module-level investigation of thermal behaviour across normal (ON), open-circuit (OC), and short-circuit (SC) states, integrating surface and air temperature measurements to assess module-level and microclimatic responses. Among the tested conditions, the transition from ON to OC exhibited the most notable and statistically significant changes. Under clear-sky conditions, OC modules were +2.1°C to +2.8°C warmer than during normal operation, while the SC state produced only minor additional warming (+1.4°C) in one module type. Beyond individual surface heating, the ON → OC transition caused a measurable adjacency effect, increasing the temperature of neighbouring modules by +6.8°C, based on irradiance-normalised estimates at ∼0.95 kW/m 2 , between 14:00 h and 15:00 h. In parallel, near-surface air at 1 m warmed by +0.56°C, reinforcing the understanding that module-level heating under OC conditions can extend into the surrounding rooftop microclimate. Material characteristics further shaped these responses, with higher-efficiency, wider-bandgap modules exhibiting greater thermal stability. Collectively, the findings provide empirical evidence that PV systems function not only as renewable energy sources but also as active thermal elements influencing rooftop microclimates across operating states. These results extend PV fault research beyond purely electrical diagnostics, introducing an integrated rooftop energy-thermal perspective directly relevant to system design, performance monitoring, and urban microclimate assessment in dense tropical environments.

Solar EnergyVol. 310
National University of Singapore (SG)
Sustainable cities and communities
Openalex Percentile: Top 35%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.