Novel partially biodegradable Ti-6Al-4V/Zn composites fabricated through hybrid additive manufacturing and powder metallurgy

This study reports the development of a Ti6Al4V-Zn metallic bi-metal composite (Ti64-Zn MBMC) engineered for biodegradable biomedical applications. The composite features a continuous additively manufactured (AM) Ti64 hexagonal lattice that provides a three-dimensional structural framework, while Zn infiltrates and occupies the interconnected pore network. Fabrication was achieved through a hybrid route combining AM and powder metallurgy, wherein the Ti64 lattice was first produced by AM, followed by Zn incorporation and consolidation via spark plasma sintering. The tomography results reveal that the composite consists of approximately 27% Ti64 reinforcement phase and 73% Zn matrix phase, confirming successful introduction of Zn within the architected Ti64 honeycomb scaffold. Microstructural characterization confirmed a crack-free interface with no detectable interfacial reactions between Ti64 and Zn. The Ti64-Zn MBMC exhibited a compressive strength of 292±25 MPa, surpassing that of both pure Zn and the Ti64 lattice. Potentiodynamic polarization in simulated body fluid (SBF) revealed corrosion behavior comparable to pure Zn, with post-corrosion microscopy showing selective dissolution of Zn while Ti64 struts remained intact. In-vitro biodegradation tests indicated an initial degradation rate of 0.1577 mm/year in SBF. Cytocompatibility assessments using MC3T3-E1 pre-osteoblasts demonstrated healthy cell proliferation in media conditioned with composite leachates. Collectively, these results establish the Ti64-Zn MBMC as a promising candidate for next-generation biodegradable implants and tissue-engineering scaffolds. • Employ hybrid fabrication strategy combining additive manufacturing and powder metallurgy. • Fabricate bio-inspired architecture for partially biodegradable implants. • Controlled degradation of implants by galvanic interactions. • Material with healthy cell proliferation and no cytotoxic effects.

Authors

Institutions

Publication Details

Journal
Advanced Light Materials
Published
2026-03-07
DOI
https://doi.org/10.1016/j.almate.2026.03.001
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel partially biodegradable Ti-6Al-4V/Zn composites fabricated through hybrid additive manufacturing and powder metallurgy

J. Jayaraj, Mayank Yadav, Sagar Nilawar, Kaushik Chatterjee et al.
Advanced Light Materials
Titanium Alloys Microstructure and Properties
article

Novel partially biodegradable Ti-6Al-4V/Zn composites fabricated through hybrid additive manufacturing and powder metallurgy

J. Jayaraj, Mayank Yadav, Sagar Nilawar, Kaushik Chatterjee, Riddhi Shukla, Chandarasekhar Perugu, K. G. Prashanth, K. Praveenkumar, Satyam Suwas
article en

Abstract

This study reports the development of a Ti6Al4V-Zn metallic bi-metal composite (Ti64-Zn MBMC) engineered for biodegradable biomedical applications. The composite features a continuous additively manufactured (AM) Ti64 hexagonal lattice that provides a three-dimensional structural framework, while Zn infiltrates and occupies the interconnected pore network. Fabrication was achieved through a hybrid route combining AM and powder metallurgy, wherein the Ti64 lattice was first produced by AM, followed by Zn incorporation and consolidation via spark plasma sintering. The tomography results reveal that the composite consists of approximately 27% Ti64 reinforcement phase and 73% Zn matrix phase, confirming successful introduction of Zn within the architected Ti64 honeycomb scaffold. Microstructural characterization confirmed a crack-free interface with no detectable interfacial reactions between Ti64 and Zn. The Ti64-Zn MBMC exhibited a compressive strength of 292±25 MPa, surpassing that of both pure Zn and the Ti64 lattice. Potentiodynamic polarization in simulated body fluid (SBF) revealed corrosion behavior comparable to pure Zn, with post-corrosion microscopy showing selective dissolution of Zn while Ti64 struts remained intact. In-vitro biodegradation tests indicated an initial degradation rate of 0.1577 mm/year in SBF. Cytocompatibility assessments using MC3T3-E1 pre-osteoblasts demonstrated healthy cell proliferation in media conditioned with composite leachates. Collectively, these results establish the Ti64-Zn MBMC as a promising candidate for next-generation biodegradable implants and tissue-engineering scaffolds. • Employ hybrid fabrication strategy combining additive manufacturing and powder metallurgy. • Fabricate bio-inspired architecture for partially biodegradable implants. • Controlled degradation of implants by galvanic interactions. • Material with healthy cell proliferation and no cytotoxic effects.

Advanced Light MaterialsVol. 1(1)
Tallinn University of Technology (EE), Dalarna University (SE), VSB - Technical University of Ostrava (CZ), Loughborough University (GB), Nanyang Technological University (SG), Water Research Institute (SK), Nanyang Institute of Technology (CN), Karlstad University (SE), Indian Institute of Science Bangalore (IN), Saveetha University (IN), South China University of Technology (CN)
Openalex Percentile: Top 32%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.