Development of a standardised biobanking workflow for molecular samples

Introduction: Biospecimen integrity and traceability are fundamental for reproducible molecular research. This study reports on the initial phase of developing a biobanking workflow to ensure consistent specimen integrity, proper traceability, readiness for long-term storage, and systematic quality verification. Materials and methods: Phase I involved three completed components: (i) preliminary verification by cross-referencing sample identifiers against approved transfer documentation and consent records; (ii) visual inspection assessing tube integrity and label legibility; and (iii) sample processing involving quality assessment and aliquoting biospecimen samples (580-600 µL) into 5–6 cryogenic tubes per specimen with standardised labelling. Phase II (planned) includes assigning samples to a −80�C freezer in Biobank Unit, Department of Pathology and Laboratory Medicine, SASMEC @IIUM, entering data into the Laboratory Information System, and implementing supervisory verification protocols. Results: The implementation of Phase I was completed successfully without major issues. The initial documentation review showed consistency between biospecimen identifiers and the accompanying records. Visual inspection confirmed that all tubes were intact, with no seal compromise; labels were legible, and samples were suitable for aliquoting. Aliquot preparation produced a uniform stock, which was stored temporarily in cold storage pending Phase II biobank allocation. Conclusion: The findings from Phase I demonstrate the feasibility of establishing standardised biospecimen processing and quality verification within an institutional biobanking framework. This documented workflow provides a foundation that, upon integration of Phase II, will enable systematic, long-term biospecimen storage, traceability, and governance to support future research needs.

Authors

Publication Details

Journal
The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Published
2026-03-02
Primary Topic
Molecular Biology Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a standardised biobanking workflow for molecular samples

Nour El Huda Abd. Rahim, Khairunisa Ahmad Affandi, Wan Noorainna Fatimi Wan Mohd Zani, Norlelawati A.Talib et al.
The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Molecular Biology Techniques and Applications
article

Development of a standardised biobanking workflow for molecular samples

Nour El Huda Abd. Rahim, Khairunisa Ahmad Affandi, Wan Noorainna Fatimi Wan Mohd Zani, Norlelawati A.Talib, Nur Fasihah Mat Puat, Muhammad Qamarul Izzat Mohd Rodzi, Nur Ilma A'isyah Azrul
article en

Abstract

Introduction: Biospecimen integrity and traceability are fundamental for reproducible molecular research. This study reports on the initial phase of developing a biobanking workflow to ensure consistent specimen integrity, proper traceability, readiness for long-term storage, and systematic quality verification. Materials and methods: Phase I involved three completed components: (i) preliminary verification by cross-referencing sample identifiers against approved transfer documentation and consent records; (ii) visual inspection assessing tube integrity and label legibility; and (iii) sample processing involving quality assessment and aliquoting biospecimen samples (580-600 µL) into 5–6 cryogenic tubes per specimen with standardised labelling. Phase II (planned) includes assigning samples to a −80�C freezer in Biobank Unit, Department of Pathology and Laboratory Medicine, SASMEC @IIUM, entering data into the Laboratory Information System, and implementing supervisory verification protocols. Results: The implementation of Phase I was completed successfully without major issues. The initial documentation review showed consistency between biospecimen identifiers and the accompanying records. Visual inspection confirmed that all tubes were intact, with no seal compromise; labels were legible, and samples were suitable for aliquoting. Aliquot preparation produced a uniform stock, which was stored temporarily in cold storage pending Phase II biobank allocation. Conclusion: The findings from Phase I demonstrate the feasibility of establishing standardised biospecimen processing and quality verification within an institutional biobanking framework. This documented workflow provides a foundation that, upon integration of Phase II, will enable systematic, long-term biospecimen storage, traceability, and governance to support future research needs.

The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Partnerships for the goals, Industry, innovation and infrastructure
Openalex Percentile: Top 30%
Molecular Biology Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.