Thermal performance of modified surgical drill margins during bone drilling: An experimental, numerical, and optimization case study

Excessive heat generation during bone drilling causes thermal osteonecrosis, posing a significant risk in orthopedic and dental procedures. While various aspects of drill design have been studied, the specific influence of margin geometry remains underexplored in the context of thermal engineering. This study integrates drilling simulation, experimental validation, and statistical optimization to evaluate the thermal impact of drill margin width (<i>M</i><sub><i>w</i></sub>) and height (<i>M</i><sub><i>h</i></sub>) during cortical bone drilling. A validated thermo-mechanical model was developed using commercial software DEFORM-3D. The simulation results were validated with experimental bone drilling with small temperature prediction errors (2.4% and 8.0%). Key thermal metrics (maximum temperature (<i>T</i><sub>max</sub>), osteonecrosis diameter (OD), and osteonecrosis depth (OH)) were optimized using a central composite design (CCD) of response surface methodology (RSM) and desirability-based multi-objective optimization. Results revealed that <i>M</i><sub><i>w</i></sub> had the most significant second-order influence on <i>T</i><sub>max</sub> (47.2%), while <i>M</i><sub><i>h</i></sub> dominated OD (41.1%) and OH (47.8%). The optimal drill margins (<i>M</i><sub><i>h</i></sub> = 0.05 mm and <i>M</i><sub><i>w</i></sub> = 0.22 mm), which achieved a desirability score of 0.985, could reduce <i>T</i><sub>max</sub> by up to 44.8°C, which is below the osteonecrosis threshold. This work highlights drill margins as a critical yet previously underutilized design variable, offering an alternative pathway for the thermally optimized development of surgical tools and next-generation robotic-assisted drilling systems.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2026-03-07
DOI
https://doi.org/10.1177/09544119261426440
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal performance of modified surgical drill margins during bone drilling: An experimental, numerical, and optimization case study

M. A. Musa, Mohd Faizal Ali Akhbar, Rodianah Alias, Shahrizan Jamaludin et al.
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Dental Implant Techniques and Outcomes
article

Thermal performance of modified surgical drill margins during bone drilling: An experimental, numerical, and optimization case study

M. A. Musa, Mohd Faizal Ali Akhbar, Rodianah Alias, Shahrizan Jamaludin, Suriani Mat Jusoh, Fatin Alias
article en

Abstract

Excessive heat generation during bone drilling causes thermal osteonecrosis, posing a significant risk in orthopedic and dental procedures. While various aspects of drill design have been studied, the specific influence of margin geometry remains underexplored in the context of thermal engineering. This study integrates drilling simulation, experimental validation, and statistical optimization to evaluate the thermal impact of drill margin width (<i>M</i><sub><i>w</i></sub>) and height (<i>M</i><sub><i>h</i></sub>) during cortical bone drilling. A validated thermo-mechanical model was developed using commercial software DEFORM-3D. The simulation results were validated with experimental bone drilling with small temperature prediction errors (2.4% and 8.0%). Key thermal metrics (maximum temperature (<i>T</i><sub>max</sub>), osteonecrosis diameter (OD), and osteonecrosis depth (OH)) were optimized using a central composite design (CCD) of response surface methodology (RSM) and desirability-based multi-objective optimization. Results revealed that <i>M</i><sub><i>w</i></sub> had the most significant second-order influence on <i>T</i><sub>max</sub> (47.2%), while <i>M</i><sub><i>h</i></sub> dominated OD (41.1%) and OH (47.8%). The optimal drill margins (<i>M</i><sub><i>h</i></sub> = 0.05 mm and <i>M</i><sub><i>w</i></sub> = 0.22 mm), which achieved a desirability score of 0.985, could reduce <i>T</i><sub>max</sub> by up to 44.8°C, which is below the osteonecrosis threshold. This work highlights drill margins as a critical yet previously underutilized design variable, offering an alternative pathway for the thermally optimized development of surgical tools and next-generation robotic-assisted drilling systems.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Universiti Malaysia Terengganu (MY), Sultan Zainal Abidin University (MY)
Openalex Percentile: Top 29%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.