Validation of an artificial intelligence-driven novel microphone-based wireless jaw movement and respiratory event detection system for home sleep apnea testing

Home sleep apnea testing (HSAT) is increasingly used for obstructive sleep apnea (OSA) it captures sleep in natural, at-home settings. However, audio-only approaches are challenged by hardware heterogeneity and the modest association between snoring loudness and the apnea–hypopnea index (AHI). This study utilized a smartphone-recorded HSAT combining broadband respiratory audio (∼200–15,000 Hz) with a chip-less, angle-triggered ultrasonic emitter affixed to the mandible. The emitter writes narrowband tones into the same 48-kHz track—18.0 kHz as a mandibular-related anchor and 19.5 kHz as a cue—providing posture/movement anchors without inertial sensors. A multimodal AI pipeline fused handcrafted ultrasonic/audio features with learned representations from SoundSleepNet and a Vision Transformer (ViT), integrated by a Deep Neural Decision Forest (DNDF) to label 30-s epochs (Awake/Normal/Event). HSAT-derived AHI was compared with simultaneous polysomnography (PSG) scored per AASM-2023 rules (hypopnea defined according to the AASM recommended criteria, requiring a ≥3% oxygen desaturation or an associated EEG arousal) in a prospective single-center cohort ( ClinicalTrials.gov NCT06862297; n = 96). SoundSleepNet many-to-many outperformed single-to-single modeling while ViT achieved optimal accuracy using the embedded 19,475–19,525 Hz band. In the prediction set, DNDF-AHI correlated with PSG-AHI (R 2 = 0.6986) with a mean Bland–Altman bias of +5.85 (95% limits −24.24 to +35.94) events·h −1 . OSA-severity accuracy was 92% for binary scheme (AHI ≥ 15 vs <15) with 90% sensitivity and 85% specificity. Integrating ultrasonic mandibular markers with audio-based AI and DNDF enable accurate binary discrimination of moderate-to-severe OSA, supporting scalable, posture-aware HSAT screening and longitudinal management.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-03-07
DOI
https://doi.org/10.1016/j.bspc.2026.110008
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an artificial intelligence-driven novel microphone-based wireless jaw movement and respiratory event detection system for home sleep apnea testing

Jowy Tani, Yulia Aurora, Shu-Chuan Ho, Chih-Shan Huang et al.
Biomedical Signal Processing and Control
Obstructive Sleep Apnea Research
article

Validation of an artificial intelligence-driven novel microphone-based wireless jaw movement and respiratory event detection system for home sleep apnea testing

Jowy Tani, Yulia Aurora, Shu-Chuan Ho, Chih-Shan Huang, Shih-Jo Ho, Yuan-Ching Chung
article en

Abstract

Home sleep apnea testing (HSAT) is increasingly used for obstructive sleep apnea (OSA) it captures sleep in natural, at-home settings. However, audio-only approaches are challenged by hardware heterogeneity and the modest association between snoring loudness and the apnea–hypopnea index (AHI). This study utilized a smartphone-recorded HSAT combining broadband respiratory audio (∼200–15,000 Hz) with a chip-less, angle-triggered ultrasonic emitter affixed to the mandible. The emitter writes narrowband tones into the same 48-kHz track—18.0 kHz as a mandibular-related anchor and 19.5 kHz as a cue—providing posture/movement anchors without inertial sensors. A multimodal AI pipeline fused handcrafted ultrasonic/audio features with learned representations from SoundSleepNet and a Vision Transformer (ViT), integrated by a Deep Neural Decision Forest (DNDF) to label 30-s epochs (Awake/Normal/Event). HSAT-derived AHI was compared with simultaneous polysomnography (PSG) scored per AASM-2023 rules (hypopnea defined according to the AASM recommended criteria, requiring a ≥3% oxygen desaturation or an associated EEG arousal) in a prospective single-center cohort ( ClinicalTrials.gov NCT06862297; n = 96). SoundSleepNet many-to-many outperformed single-to-single modeling while ViT achieved optimal accuracy using the embedded 19,475–19,525 Hz band. In the prediction set, DNDF-AHI correlated with PSG-AHI (R 2 = 0.6986) with a mean Bland–Altman bias of +5.85 (95% limits −24.24 to +35.94) events·h −1 . OSA-severity accuracy was 92% for binary scheme (AHI ≥ 15 vs <15) with 90% sensitivity and 85% specificity. Integrating ultrasonic mandibular markers with audio-based AI and DNDF enable accurate binary discrimination of moderate-to-severe OSA, supporting scalable, posture-aware HSAT screening and longitudinal management.

Biomedical Signal Processing and ControlVol. 120
Waseda University (JP), National Taiwan University (TW), National Taipei University of Nursing and Health Science (TW), Taipei Medical University Hospital (TW), GenMont Biotech (Taiwan) (TW), Wan Fang Hospital (TW), Taipei Medical University-Shuang Ho Hospital (TW), Taipei Medical University (TW), University of Sheffield (GB)
Zero hunger
Openalex Percentile: Top 29%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.