A novel anterior occipitocervical fixation instrument improves stability and minimizes bone-implant stress: a comparative finite element analysis

Purpose Posterior fixation is commonly the preferred surgical method for occipitocervical instability. In certain cases, posterior surgery no longer holds an advantage, and it is more advisable to choose the anterior approach. Furthermore, some internal fixation failures are stress-related. Therefore, we designed three types of anterior fixation instruments and evaluated them via finite element analysis, aiming to identify a design that enhances stability while minimizing stress at the bone-implant interface.Methods We performed a finite element analysis using a validated C0-C2 model with simulated instability. Three distinct instruments were virtually implanted: Occipital Condylar Plate (OCP); Atlanto-Occipital Transarticular Plate (AOP); and Atlantoaxial-Occipital Plate (AAOP). We applied a 40-N axial load and 1.5-Nm moments to simulate flexion, extension, lateral bending, and axial rotation. Segmental range of motion (ROM) and von Mises stress at the implant and bone were analyzed.Results All three instruments increased stability. However, the OCP design was markedly superior, reducing flexion ROM by 50-61.54% compared to the AOP and AAOP, respectively. Most critically, the OCP demonstrated the lowest von Mises stress at the bone across all motion states. Its stress distribution was also the most uniform, in stark contrast to the high stress concentrations observed with the other designs.Conclusions Among the three instruments, the OCP provides the most robust stability and, crucially, the most favorable stress environment, which may reduce the clinical risk of stress-related internal fixation failure.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2026-03-07
DOI
https://doi.org/10.1186/s13018-026-06741-3
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel anterior occipitocervical fixation instrument improves stability and minimizes bone-implant stress: a comparative finite element analysis

Hang Xiao, Panjie Xu, X. Zhang, Yue Wang et al.
Journal of Orthopaedic Surgery and Research
Spinal Fractures and Fixation Techniques
article

A novel anterior occipitocervical fixation instrument improves stability and minimizes bone-implant stress: a comparative finite element analysis

Hang Xiao, Panjie Xu, X. Zhang, Yue Wang, Jianying Zheng, Jian Xiong, Wei Ji
article en

Abstract

Purpose Posterior fixation is commonly the preferred surgical method for occipitocervical instability. In certain cases, posterior surgery no longer holds an advantage, and it is more advisable to choose the anterior approach. Furthermore, some internal fixation failures are stress-related. Therefore, we designed three types of anterior fixation instruments and evaluated them via finite element analysis, aiming to identify a design that enhances stability while minimizing stress at the bone-implant interface.Methods We performed a finite element analysis using a validated C0-C2 model with simulated instability. Three distinct instruments were virtually implanted: Occipital Condylar Plate (OCP); Atlanto-Occipital Transarticular Plate (AOP); and Atlantoaxial-Occipital Plate (AAOP). We applied a 40-N axial load and 1.5-Nm moments to simulate flexion, extension, lateral bending, and axial rotation. Segmental range of motion (ROM) and von Mises stress at the implant and bone were analyzed.Results All three instruments increased stability. However, the OCP design was markedly superior, reducing flexion ROM by 50-61.54% compared to the AOP and AAOP, respectively. Most critically, the OCP demonstrated the lowest von Mises stress at the bone across all motion states. Its stress distribution was also the most uniform, in stark contrast to the high stress concentrations observed with the other designs.Conclusions Among the three instruments, the OCP provides the most robust stability and, crucially, the most favorable stress environment, which may reduce the clinical risk of stress-related internal fixation failure.

Journal of Orthopaedic Surgery and Research
Yuncheng University (CN), Ganzhou People's Hospital (CN), Nanfang Hospital (CN), Southern Medical University (CN)
Openalex Percentile: Top 30%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.