Posterior C1-2 Fusion Using Large-Diameter C2 Pars and Intralaminar Screws in the Setting of a High-Riding Vertebral Artery: A Case Report

A high-riding vertebral artery (HRVA) narrows the C2 pedicle corridor and increases the risk of vertebral artery injury during C2 pedicle or transarticular screw placement. Selecting an anchor that preserves safety without compromising stability remains challenging in such cases. A 32-year-old man with Down syndrome presented with neck and left-sided limb pain, left-hand clumsiness, and gait disturbance. Imaging showed atlantoaxial subluxation (AAS) with left HRVA. We performed posterior C1-2 fusion using a large-diameter C2 pars screw together with a C2 intralaminar screw on the HRVA side, plus a C1 lateral mass screw and a contralateral C2 pedicle screw. Postoperatively, symptoms improved, and no implant-related complications were observed at one-year follow-up. In AAS complicated by HRVA, a large-diameter C2 pars plus intralaminar screw construct can secure a safe trajectory while achieving satisfactory initial stability and clinical improvement. This hybrid strategy may serve as a practical alternative when a C2 pedicle trajectory is unsafe.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-03-04
DOI
https://doi.org/10.7759/cureus.104688
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Posterior C1-2 Fusion Using Large-Diameter C2 Pars and Intralaminar Screws in the Setting of a High-Riding Vertebral Artery: A Case Report

Takashi Hozumi, Satoshi Maki, Yuhi YOSHIKAWA, Seiji Ohtori et al.
Cureus
Spinal Fractures and Fixation Techniques
article

Posterior C1-2 Fusion Using Large-Diameter C2 Pars and Intralaminar Screws in the Setting of a High-Riding Vertebral Artery: A Case Report

Takashi Hozumi, Satoshi Maki, Yuhi YOSHIKAWA, Seiji Ohtori, Takahiro Mori
article en

Abstract

A high-riding vertebral artery (HRVA) narrows the C2 pedicle corridor and increases the risk of vertebral artery injury during C2 pedicle or transarticular screw placement. Selecting an anchor that preserves safety without compromising stability remains challenging in such cases. A 32-year-old man with Down syndrome presented with neck and left-sided limb pain, left-hand clumsiness, and gait disturbance. Imaging showed atlantoaxial subluxation (AAS) with left HRVA. We performed posterior C1-2 fusion using a large-diameter C2 pars screw together with a C2 intralaminar screw on the HRVA side, plus a C1 lateral mass screw and a contralateral C2 pedicle screw. Postoperatively, symptoms improved, and no implant-related complications were observed at one-year follow-up. In AAS complicated by HRVA, a large-diameter C2 pars plus intralaminar screw construct can secure a safe trajectory while achieving satisfactory initial stability and clinical improvement. This hybrid strategy may serve as a practical alternative when a C2 pedicle trajectory is unsafe.

Cureus
Chiba University (JP)
Good health and well-being
Openalex Percentile: Top 32%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.