Deep spatiotemporal feature fusion using CNN-LSTM autoencoder for real-time, phase-aware anomaly identification and localization in high-voltage power transmission networks

• Hybrid CNN–LSTM–Autoencoder enables phase-aware fault detection and localization. • Achieves 99.5% detection and 98.5% phase-level localization accuracy. • Reconstruction errors and thresholds provide interpretable fault analysis. • Outperforms state-of-the-art models in accuracy and robustness for smart grids. Reliable fault detection and phase-level fault localization in three-phase power transmission systems remain challenging due to increasing grid nonlinearity and dynamic operating conditions in modern smart grids. Conventional protection schemes and data-driven approaches often exhibit limited adaptability, poor generalization to unseen operating conditions, and insufficient capability for precise phase-wise fault identification. Recent deep learning-based methods primarily focus on fault classification and rely on supervised learning and heuristic decision thresholds, limiting their interpretability and practical deployment. To address these limitations, this paper proposes a novel spatiotemporal deep learning framework based on a hybrid CNN–LSTM–Autoencoder (CNN–LSTM–AE) architecture that integrates spatial feature extraction, temporal dependency modeling, and unsupervised reconstruction-based anomaly analysis within a unified system. A key innovation is a phase-wise reconstruction error profiling mechanism that enables identification of faulty phases and characterization of faults, with an adaptive thresholding strategy to enhance interpretability. The proposed framework is trained and validated using real-world transmission voltage and current measurements and evaluated under diverse fault scenarios and operating conditions. Comparative results demonstrate superior fault detection and localization performance compared with conventional CNN, LSTM, and hybrid deep learning models, with improved robustness and reduced false-positive rates. This unified, interpretable fault intelligence framework provides a scalable solution for real-time protection and self-healing operations in next-generation smart grid transmission systems.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-03-05
DOI
https://doi.org/10.1016/j.rineng.2026.109900
Primary Topic
Electricity Theft Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep spatiotemporal feature fusion using CNN-LSTM autoencoder for real-time, phase-aware anomaly identification and localization in high-voltage power transmission networks

Chowdhury Akram Hossain, Md. Rifat Hazari, Nasif Hannan, Abu Shufian et al.
Results in Engineering
Electricity Theft Detection Techniques
article

Deep spatiotemporal feature fusion using CNN-LSTM autoencoder for real-time, phase-aware anomaly identification and localization in high-voltage power transmission networks

Chowdhury Akram Hossain, Md. Rifat Hazari, Nasif Hannan, Abu Shufian, Md Nazmun Nur, Aftab Alam Asif, Abdullah Al Mujahid
article en

Abstract

• Hybrid CNN–LSTM–Autoencoder enables phase-aware fault detection and localization. • Achieves 99.5% detection and 98.5% phase-level localization accuracy. • Reconstruction errors and thresholds provide interpretable fault analysis. • Outperforms state-of-the-art models in accuracy and robustness for smart grids. Reliable fault detection and phase-level fault localization in three-phase power transmission systems remain challenging due to increasing grid nonlinearity and dynamic operating conditions in modern smart grids. Conventional protection schemes and data-driven approaches often exhibit limited adaptability, poor generalization to unseen operating conditions, and insufficient capability for precise phase-wise fault identification. Recent deep learning-based methods primarily focus on fault classification and rely on supervised learning and heuristic decision thresholds, limiting their interpretability and practical deployment. To address these limitations, this paper proposes a novel spatiotemporal deep learning framework based on a hybrid CNN–LSTM–Autoencoder (CNN–LSTM–AE) architecture that integrates spatial feature extraction, temporal dependency modeling, and unsupervised reconstruction-based anomaly analysis within a unified system. A key innovation is a phase-wise reconstruction error profiling mechanism that enables identification of faulty phases and characterization of faults, with an adaptive thresholding strategy to enhance interpretability. The proposed framework is trained and validated using real-world transmission voltage and current measurements and evaluated under diverse fault scenarios and operating conditions. Comparative results demonstrate superior fault detection and localization performance compared with conventional CNN, LSTM, and hybrid deep learning models, with improved robustness and reduced false-positive rates. This unified, interpretable fault intelligence framework provides a scalable solution for real-time protection and self-healing operations in next-generation smart grid transmission systems.

Results in EngineeringVol. 30
American International University-Bangladesh (BD)
Affordable and clean energy
Openalex Percentile: Top 34%
Electricity Theft Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.