A hybrid admittance control strategy for fluid-driven origami actuators in lower limb exoskeleton

• A hybrid admittance control strategy is developed for a FOAM-actuated knee exoskeleton. • Neural network compensation enhances adaptability to nonlinear actuator behavior. • EMG-based fuzzy logic enables real-time adjustment of assistive torque according to user effort. • The controller ensures high stability with an RMSE of 1.944 ± 0.447 Nm during knee motion tasks. • Demonstrates robust adaptability under varying user exertion and external loads. A hybrid admittance control strategy is proposed for a lower limb exoskeleton actuated by a fluid-driven origami-inspired artificial muscle (FOAM). This approach combines the force-responsive characteristics of conventional admittance control with the adaptive learning capability of neural networks to assist human subjects during knee rehabilitation. To determine the appropriate level of assistive force, electromyography (EMG) signals are incorporated via fuzzy logic control, thereby promoting optimal muscle engagement throughout the recovery process. The experimental results validate the controller's ability to maintain performance despite external load variations and unpredictable user exertion. This robustness is critical for managing the nonlinear dynamics inherent in exoskeleton actuation, ensuring consistent assistance across diverse operating conditions. Performance evaluation reports a root mean square error (RMSE) of 1.944 ± 0.447 Nm under hybrid admittance control, indicating high stability and adaptability of assistive torque output in response to varying muscular effort. To affirm the feasibility and adaptability of the proposed strategy, the experimental validation is conducted under controlled laboratory conditions. These findings highlight the potential of the proposed system to enhance human–robot interaction and broaden the applicability of exoskeletons in diverse rehabilitation scenarios.

Authors

Institutions

Publication Details

Journal
Robotics and Autonomous Systems
Published
2026-03-05
DOI
https://doi.org/10.1016/j.robot.2026.105416
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hybrid admittance control strategy for fluid-driven origami actuators in lower limb exoskeleton

Teeranoot Chanthasopeephan, Nonthaphat Prakongpak
Robotics and Autonomous Systems
Prosthetics and Rehabilitation Robotics
article

A hybrid admittance control strategy for fluid-driven origami actuators in lower limb exoskeleton

Teeranoot Chanthasopeephan, Nonthaphat Prakongpak
article en

Abstract

• A hybrid admittance control strategy is developed for a FOAM-actuated knee exoskeleton. • Neural network compensation enhances adaptability to nonlinear actuator behavior. • EMG-based fuzzy logic enables real-time adjustment of assistive torque according to user effort. • The controller ensures high stability with an RMSE of 1.944 ± 0.447 Nm during knee motion tasks. • Demonstrates robust adaptability under varying user exertion and external loads. A hybrid admittance control strategy is proposed for a lower limb exoskeleton actuated by a fluid-driven origami-inspired artificial muscle (FOAM). This approach combines the force-responsive characteristics of conventional admittance control with the adaptive learning capability of neural networks to assist human subjects during knee rehabilitation. To determine the appropriate level of assistive force, electromyography (EMG) signals are incorporated via fuzzy logic control, thereby promoting optimal muscle engagement throughout the recovery process. The experimental results validate the controller's ability to maintain performance despite external load variations and unpredictable user exertion. This robustness is critical for managing the nonlinear dynamics inherent in exoskeleton actuation, ensuring consistent assistance across diverse operating conditions. Performance evaluation reports a root mean square error (RMSE) of 1.944 ± 0.447 Nm under hybrid admittance control, indicating high stability and adaptability of assistive torque output in response to varying muscular effort. To affirm the feasibility and adaptability of the proposed strategy, the experimental validation is conducted under controlled laboratory conditions. These findings highlight the potential of the proposed system to enhance human–robot interaction and broaden the applicability of exoskeletons in diverse rehabilitation scenarios.

Robotics and Autonomous SystemsVol. 201
King Mongkut's University of Technology Thonburi (TH)
Openalex Percentile: Top 34%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.