Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography

Background:We aimed to evaluate the effects of different incident directions on organ-absorbed doses, effective doses, and effective dose conversion coefficients for chest radiography. Materials and Methods:We constructed an examination environment for chest radiography using a Monte Carlo simulation and estimated the organ-absorbed doses and effective doses for frontal anterior-posterior (AP), frontal posterior-anterior (PA), left lateral, and right lateral radiography.The effective dose conversion coefficients were calculated using the air kerma-area product.Results and Discussion: Some organs, such as the breast, showed more than a fivefold difference in the organ-absorbed dose between AP and PA radiography.In lateral radiography, there was a large difference in the organ-absorbed doses in the abdominal region.The effective dose was approximately 30% higher for AP radiography than for PA radiography.The effective dose conversion coefficients differed between AP and PA radiography.These findings are consistent with the anatomical arrangement of organs in the human body; nevertheless, they have not been explicitly reported in previous studies. Conclusion:It was suggested that using the PA direction of incidence in frontal radiography reduces the effective dose received by the patient.In addition, when estimating the effective dose using conversion coefficients, the estimated value may differ significantly due to differences in the direction of incidence, so the coefficients must be appropriately selected.

Authors

Publication Details

Journal
Journal of Radiation Protection and Research
Published
2026-03-05
DOI
https://doi.org/10.14407/jrpr.2025.00241
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography

Koji Ono, Yasuki Asada
Journal of Radiation Protection and Research
Advanced Radiotherapy Techniques
article

Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography

Koji Ono, Yasuki Asada
article en

Abstract

Background:We aimed to evaluate the effects of different incident directions on organ-absorbed doses, effective doses, and effective dose conversion coefficients for chest radiography. Materials and Methods:We constructed an examination environment for chest radiography using a Monte Carlo simulation and estimated the organ-absorbed doses and effective doses for frontal anterior-posterior (AP), frontal posterior-anterior (PA), left lateral, and right lateral radiography.The effective dose conversion coefficients were calculated using the air kerma-area product.Results and Discussion: Some organs, such as the breast, showed more than a fivefold difference in the organ-absorbed dose between AP and PA radiography.In lateral radiography, there was a large difference in the organ-absorbed doses in the abdominal region.The effective dose was approximately 30% higher for AP radiography than for PA radiography.The effective dose conversion coefficients differed between AP and PA radiography.These findings are consistent with the anatomical arrangement of organs in the human body; nevertheless, they have not been explicitly reported in previous studies. Conclusion:It was suggested that using the PA direction of incidence in frontal radiography reduces the effective dose received by the patient.In addition, when estimating the effective dose using conversion coefficients, the estimated value may differ significantly due to differences in the direction of incidence, so the coefficients must be appropriately selected.

Journal of Radiation Protection and Research
Good health and well-being
Openalex Percentile: Top 29%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.