Shining a light on viral detection: a comparative study of electrochemical and electrochemiluminescence techniques for human cytomegalovirus

Human cytomegalovirus (hCMV) is a widespread herpesvirus proposed to exert oncomodulatory effects on several cancers by influencing cell proliferation, inflammation, and immune evasion. hCMV DNA and proteins have been detected in tumors, such as glioblastoma and colorectal cancer, suggesting a possible role in tumor biology. However, detection rates in clinical samples vary dramatically from 0 to 100%, reflecting both biological heterogeneity and methodological differences. Standard detection methods such as immunohistochemistry, qPCR, and sequencing provide good sensitivity, but each has limitations, including inconsistent antibody performance, costly instrumentation, and limited suitability for routine screening in point-of-care settings. Electrochemical (EC) and electrogenerated chemiluminescence (ECL) bioassays and biosensors offer attractive alternatives, providing rapid, simple, and low-sample-consumption assays that are well suited for point-of-care testing. These platforms combine high analytical sensitivity with minimal instrumentation requirements, short turnaround times, and compatibility with amplification strategies, making them promising tools for decentralized viral diagnostics. In this study, we optimized and compared EC and ECL bioassays coupled with various amplification strategies, including PCR, recombinase polymerase amplification (RPA), and loop-mediated isothermal amplification (LAMP), for hCMV detection in real samples. Amperometric EC readout combined with PCR or RPA showed high specificity, reliably distinguishing hCMV-infected from uninfected cells, and demonstrating its potential for use in tumor tissue analysis. LAMP offers excellent sensitivity but suffers from nonspecific amplification, whereas the ECL assay failed to detect viral DNA under our conditions. These results highlight the relative strengths and limitations of these platforms and indicate their suitability for future hCMV diagnostics.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-03-05
DOI
https://doi.org/10.1007/s00216-026-06410-8
Primary Topic
Cytomegalovirus and herpesvirus research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shining a light on viral detection: a comparative study of electrochemical and electrochemiluminescence techniques for human cytomegalovirus

Aneta Fried, Karolina Itterheimova, Ludmila Moranova, Martin Bartosik
Analytical and Bioanalytical Chemistry
Cytomegalovirus and herpesvirus research
article

Shining a light on viral detection: a comparative study of electrochemical and electrochemiluminescence techniques for human cytomegalovirus

Aneta Fried, Karolina Itterheimova, Ludmila Moranova, Martin Bartosik
article en

Abstract

Human cytomegalovirus (hCMV) is a widespread herpesvirus proposed to exert oncomodulatory effects on several cancers by influencing cell proliferation, inflammation, and immune evasion. hCMV DNA and proteins have been detected in tumors, such as glioblastoma and colorectal cancer, suggesting a possible role in tumor biology. However, detection rates in clinical samples vary dramatically from 0 to 100%, reflecting both biological heterogeneity and methodological differences. Standard detection methods such as immunohistochemistry, qPCR, and sequencing provide good sensitivity, but each has limitations, including inconsistent antibody performance, costly instrumentation, and limited suitability for routine screening in point-of-care settings. Electrochemical (EC) and electrogenerated chemiluminescence (ECL) bioassays and biosensors offer attractive alternatives, providing rapid, simple, and low-sample-consumption assays that are well suited for point-of-care testing. These platforms combine high analytical sensitivity with minimal instrumentation requirements, short turnaround times, and compatibility with amplification strategies, making them promising tools for decentralized viral diagnostics. In this study, we optimized and compared EC and ECL bioassays coupled with various amplification strategies, including PCR, recombinase polymerase amplification (RPA), and loop-mediated isothermal amplification (LAMP), for hCMV detection in real samples. Amperometric EC readout combined with PCR or RPA showed high specificity, reliably distinguishing hCMV-infected from uninfected cells, and demonstrating its potential for use in tumor tissue analysis. LAMP offers excellent sensitivity but suffers from nonspecific amplification, whereas the ECL assay failed to detect viral DNA under our conditions. These results highlight the relative strengths and limitations of these platforms and indicate their suitability for future hCMV diagnostics.

Analytical and Bioanalytical Chemistry
Masaryk University (CZ), Masaryk Memorial Cancer Institute (CZ)
Openalex Percentile: Top 34%
Cytomegalovirus and herpesvirus research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.