Comparative Evaluation of Fire Performance Predictions for Glulam and CLT Under International Design Standards

Mass timber elements such as glued laminated timber (Glulam) and cross-laminated timber (CLT) have become increasingly prominent in sustainable construction due to their structural efficiency and reduced environmental impact. However, fire performance remains a critical consideration for structural safety. This paper presents a comparative assessment of experimentally measured and code-predicted fire performance parameters for Glulam and CLT, including charring rate, effective charring depth, zero-strength layer (ZSL) thickness, and residual mechanical properties. The evaluation covers major international fire design standards: Eurocode 5 (EC5), the Australian Standard (AS/NZS 1720.4), the Swedish Handbook (Swedish), American Wood Council (AWC TR10), and the Canadian Standard (CSA O86). Across all Glulam datasets, charring rate predictions agreed with tests within approximately ±20%, while AS/NZS 1720.4 consistently over predicted charring and effective char depth by around 40%. In contrast, CLT demonstrates greater variability, primarily due to adhesive degradation, delamination, and lamella orientation, which influence heat transfer and post-fire capacity. CLT data exhibited higher scatter, with effective charring depth showing standard deviations of approximately 30 to 40%, ZSL thickness averaging about 2.5 times the typical 7 mm assumption, and residual stiffness commonly reducing to around 20 to 25% of initial values after standard fire exposure. Overall, findings suggest that current standards adequately address Glulam performance but require refinement to capture the complex fire response of CLT. Continued experimental research and targeted code development, particularly within the Australian Standard, are essential to improve reliability and confidence in performance-based fire design for mass timber structures.

Authors

Institutions

Publication Details

Journal
Journal of Composites Science
Published
2026-03-05
DOI
https://doi.org/10.3390/jcs10030140
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Fire Performance Predictions for Glulam and CLT Under International Design Standards

Tharaka Gunawardena, Sumita Maharjan, P. Mendis
Journal of Composites Science
Wood Treatment and Properties
article

Comparative Evaluation of Fire Performance Predictions for Glulam and CLT Under International Design Standards

Tharaka Gunawardena, Sumita Maharjan, P. Mendis
article en

Abstract

Mass timber elements such as glued laminated timber (Glulam) and cross-laminated timber (CLT) have become increasingly prominent in sustainable construction due to their structural efficiency and reduced environmental impact. However, fire performance remains a critical consideration for structural safety. This paper presents a comparative assessment of experimentally measured and code-predicted fire performance parameters for Glulam and CLT, including charring rate, effective charring depth, zero-strength layer (ZSL) thickness, and residual mechanical properties. The evaluation covers major international fire design standards: Eurocode 5 (EC5), the Australian Standard (AS/NZS 1720.4), the Swedish Handbook (Swedish), American Wood Council (AWC TR10), and the Canadian Standard (CSA O86). Across all Glulam datasets, charring rate predictions agreed with tests within approximately ±20%, while AS/NZS 1720.4 consistently over predicted charring and effective char depth by around 40%. In contrast, CLT demonstrates greater variability, primarily due to adhesive degradation, delamination, and lamella orientation, which influence heat transfer and post-fire capacity. CLT data exhibited higher scatter, with effective charring depth showing standard deviations of approximately 30 to 40%, ZSL thickness averaging about 2.5 times the typical 7 mm assumption, and residual stiffness commonly reducing to around 20 to 25% of initial values after standard fire exposure. Overall, findings suggest that current standards adequately address Glulam performance but require refinement to capture the complex fire response of CLT. Continued experimental research and targeted code development, particularly within the Australian Standard, are essential to improve reliability and confidence in performance-based fire design for mass timber structures.

Journal of Composites ScienceVol. 10(3)
The University of Melbourne (AU)
Australian Government
Openalex Percentile: Top 34%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.