Heat transfer analysis of thawing behavior in artificially frozen subway cross passage under seepage conditions

The thawing process of artificially frozen strata has received growing attention in engineering practice. Groundwater seepage significantly influences thawing behavior in highly permeable sandy gravel strata. To expedite the thawing and meet strict engineering schedules, forced thawing techniques are often employed. However, predicting the variation in stratum thawing temperature under the combined effects of multiple factors remains challenging. This unpredictability results in a lack of a reliable quantitative basis for assessing the environmental impacts of thawing. This study conducted model tests to systematically investigate the temperature distribution within strata during both natural and forced thawing. Then, the soil freezing characteristic curve of sandy gravel was incorporated to optimize a heat-hydraulic coupling numerical model. Furthermore, the influences of multiple key factors on stratum thawing were analyzed in detail. Finally, suggestions for selecting stratum thawing methods were proposed, and the implementation scheme for forced thawing was optimized. The findings indicate that increases in groundwater seepage velocity and temperature can effectively accelerate stratum thawing, and natural thawing is sufficient to meet the thawing requirements in most engineering scenarios. Compared with natural thawing, forced thawing can reduce the thawing duration by 83.71%, making it more suitable for strata with low seepage velocity and temperature. The optimized forced thawing method not only ensures thawing efficiency but also minimizes the waste of excess heat. These research outcomes provide valuable technical guidance for the selecting thawing methods in similar engineering projects.

Authors

Institutions

Publication Details

Journal
Tunnelling and Underground Space Technology
Published
2026-03-05
DOI
https://doi.org/10.1016/j.tust.2026.107594
Primary Topic
Climate change and permafrost
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat transfer analysis of thawing behavior in artificially frozen subway cross passage under seepage conditions

Yupeng Shen, Xin Liu, Jun Zhi, Yunxi Han et al.
Tunnelling and Underground Space Technology
Climate change and permafrost
article

Heat transfer analysis of thawing behavior in artificially frozen subway cross passage under seepage conditions

Yupeng Shen, Xin Liu, Jun Zhi, Yunxi Han, Weigang Bi
article en

Abstract

The thawing process of artificially frozen strata has received growing attention in engineering practice. Groundwater seepage significantly influences thawing behavior in highly permeable sandy gravel strata. To expedite the thawing and meet strict engineering schedules, forced thawing techniques are often employed. However, predicting the variation in stratum thawing temperature under the combined effects of multiple factors remains challenging. This unpredictability results in a lack of a reliable quantitative basis for assessing the environmental impacts of thawing. This study conducted model tests to systematically investigate the temperature distribution within strata during both natural and forced thawing. Then, the soil freezing characteristic curve of sandy gravel was incorporated to optimize a heat-hydraulic coupling numerical model. Furthermore, the influences of multiple key factors on stratum thawing were analyzed in detail. Finally, suggestions for selecting stratum thawing methods were proposed, and the implementation scheme for forced thawing was optimized. The findings indicate that increases in groundwater seepage velocity and temperature can effectively accelerate stratum thawing, and natural thawing is sufficient to meet the thawing requirements in most engineering scenarios. Compared with natural thawing, forced thawing can reduce the thawing duration by 83.71%, making it more suitable for strata with low seepage velocity and temperature. The optimized forced thawing method not only ensures thawing efficiency but also minimizes the waste of excess heat. These research outcomes provide valuable technical guidance for the selecting thawing methods in similar engineering projects.

Tunnelling and Underground Space TechnologyVol. 173
Beijing Jiaotong University (CN), Chongqing Jiaotong University (CN)
Climate action
Openalex Percentile: Top 52%
Climate change and permafrost
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.