Contrast-Free Myocardial Infarction Segmentation with Attention U-Net

<b>Background:</b> Cardiovascular magnetic resonance (CMR) is the clinical gold standard for assessing cardiac anatomy and function. However, the manual segmentation of cardiac structures and myocardial infarction (MI) is time-consuming, prone to inter-observer variability, and often depends on contrast-enhanced imaging. Although deep learning (DL) has enabled substantial automation, challenges remain in generalizability, particularly for MI detection from non-contrast cine CMR. <b>Objective:</b> This study proposes a comprehensive DL-based framework for automatic segmentation of cardiac structures and myocardial infarction using contrast-free cine CMR. <b>Methods:</b> The framework integrates multiple convolutional neural network (CNN) architectures for cardiac structure segmentation with an attention-based deep learning model for MI localization. Post-processing refinement using stacked autoencoders and active contour modeling is applied to improve anatomical consistency. Segmentation performance is evaluated using overlap-based and boundary-based metrics, including the Dice Similarity Coefficient (DSC), Mean Contour Distance (MCD), and Hausdorff Distance (HD). <b>Results:</b> The best-performing model achieved Dice scores of 0.93 ± 0.05 for the left ventricular (LV) cavity, 0.89 ± 0.04 for the LV myocardium, and 0.91 ± 0.06 for the right ventricular (RV) cavity, with consistently low boundary errors across all structures. Myocardial infarction segmentation achieved a Dice score of 0.80 ± 0.02 with high recall, demonstrating reliable infarct localization without the use of contrast agents. <b>Conclusions:</b> By enabling accurate cardiac structure and myocardial infarction segmentation from contrast-free cine CMR, the proposed framework supports broader clinical applicability, particularly for patients with contraindications to gadolinium-based contrast agents and in emergency or resource-limited settings. This approach facilitates scalable, contrast-independent cardiac assessment.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-03-04
DOI
https://doi.org/10.3390/diagnostics16050768
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contrast-Free Myocardial Infarction Segmentation with Attention U-Net

Vladislava Kapravchuk, Andrey Briko, Khaled Ali Deeb, Amaliya Latypova et al.
Diagnostics
Cardiac Imaging and Diagnostics
article

Contrast-Free Myocardial Infarction Segmentation with Attention U-Net

Vladislava Kapravchuk, Andrey Briko, Khaled Ali Deeb, Amaliya Latypova, Hala Hammoud, Yasmeen Alshelle, Alexey Tikhomirov
article en

Abstract

<b>Background:</b> Cardiovascular magnetic resonance (CMR) is the clinical gold standard for assessing cardiac anatomy and function. However, the manual segmentation of cardiac structures and myocardial infarction (MI) is time-consuming, prone to inter-observer variability, and often depends on contrast-enhanced imaging. Although deep learning (DL) has enabled substantial automation, challenges remain in generalizability, particularly for MI detection from non-contrast cine CMR. <b>Objective:</b> This study proposes a comprehensive DL-based framework for automatic segmentation of cardiac structures and myocardial infarction using contrast-free cine CMR. <b>Methods:</b> The framework integrates multiple convolutional neural network (CNN) architectures for cardiac structure segmentation with an attention-based deep learning model for MI localization. Post-processing refinement using stacked autoencoders and active contour modeling is applied to improve anatomical consistency. Segmentation performance is evaluated using overlap-based and boundary-based metrics, including the Dice Similarity Coefficient (DSC), Mean Contour Distance (MCD), and Hausdorff Distance (HD). <b>Results:</b> The best-performing model achieved Dice scores of 0.93 ± 0.05 for the left ventricular (LV) cavity, 0.89 ± 0.04 for the LV myocardium, and 0.91 ± 0.06 for the right ventricular (RV) cavity, with consistently low boundary errors across all structures. Myocardial infarction segmentation achieved a Dice score of 0.80 ± 0.02 with high recall, demonstrating reliable infarct localization without the use of contrast agents. <b>Conclusions:</b> By enabling accurate cardiac structure and myocardial infarction segmentation from contrast-free cine CMR, the proposed framework supports broader clinical applicability, particularly for patients with contraindications to gadolinium-based contrast agents and in emergency or resource-limited settings. This approach facilitates scalable, contrast-independent cardiac assessment.

DiagnosticsVol. 16(5)
Bauman Moscow State Technical University (RU)
Openalex Percentile: Top 35%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.