Non-Contact Heart Rate Estimation via Higher Harmonic Analysis Using 24-GHz Doppler Radar: Validation in Humans and Anesthetized Cat

This study presents a harmonic-based method for non-contact heart rate (HR) estimation from continuous-wave (CW) Doppler radar signals, validated across multiple species including humans and small animals (cat). Traditional frequency-domain methods struggle when the HR fundamental frequency is weak or overlaps with respiratory components. The proposed approach addresses this by identifying three higher-order HR harmonics (2nd, 3rd, and 4th) then reconstructing the HR fundamental frequency from their integer ratios (3/2, 4/3, 2/1). The algorithm processes 20-s sliding windows (1-s overlap) using bandpass filtering to remove respiratory components and HR fundamental while preserving higher harmonics, followed by Power Spectral Density (PSD) analysis. When a complete harmonic set cannot be found, the proposed algorithm switches to harmonic pair detection, enhancing robustness when one harmonic is absent or attenuated. Besides, an adaptive tolerance mechanism enables detection under non-ideal conditions. The method was validated using a public human dataset and an experimental cat dataset with varied positions (supine/prone) and anesthesia levels (1–3% isoflurane). For humans, the algorithm achieved HR Accuracy consistently above 98% with an average RMSE of 1.33 bpm (MAPE: 1.29%, MAE: 0.86 bpm) and Bland-Altman bias below 0.9 bpm. For the cat dataset, performance was even better with HR Accuracy remaining above 99%, an average RMSE of 0.39 bpm (MAPE: 0.22%, MAE: 0.30 bpm), and bias below 0.14 bpm.

Authors

Institutions

Publication Details

Journal
Signals
Published
2026-03-04
DOI
https://doi.org/10.3390/signals7020024
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Contact Heart Rate Estimation via Higher Harmonic Analysis Using 24-GHz Doppler Radar: Validation in Humans and Anesthetized Cat

Koichiro Ishibashi, Guanghao Sun, Cong-Kha Pham, Ryou Tanaka et al.
Signals
Non-Invasive Vital Sign Monitoring
article

Non-Contact Heart Rate Estimation via Higher Harmonic Analysis Using 24-GHz Doppler Radar: Validation in Humans and Anesthetized Cat

Koichiro Ishibashi, Guanghao Sun, Cong-Kha Pham, Ryou Tanaka, Huu-Son Nguyen, Masaki Kurosawa
article en

Abstract

This study presents a harmonic-based method for non-contact heart rate (HR) estimation from continuous-wave (CW) Doppler radar signals, validated across multiple species including humans and small animals (cat). Traditional frequency-domain methods struggle when the HR fundamental frequency is weak or overlaps with respiratory components. The proposed approach addresses this by identifying three higher-order HR harmonics (2nd, 3rd, and 4th) then reconstructing the HR fundamental frequency from their integer ratios (3/2, 4/3, 2/1). The algorithm processes 20-s sliding windows (1-s overlap) using bandpass filtering to remove respiratory components and HR fundamental while preserving higher harmonics, followed by Power Spectral Density (PSD) analysis. When a complete harmonic set cannot be found, the proposed algorithm switches to harmonic pair detection, enhancing robustness when one harmonic is absent or attenuated. Besides, an adaptive tolerance mechanism enables detection under non-ideal conditions. The method was validated using a public human dataset and an experimental cat dataset with varied positions (supine/prone) and anesthesia levels (1–3% isoflurane). For humans, the algorithm achieved HR Accuracy consistently above 98% with an average RMSE of 1.33 bpm (MAPE: 1.29%, MAE: 0.86 bpm) and Bland-Altman bias below 0.9 bpm. For the cat dataset, performance was even better with HR Accuracy remaining above 99%, an average RMSE of 0.39 bpm (MAPE: 0.22%, MAE: 0.30 bpm), and bias below 0.14 bpm.

SignalsVol. 7(2)
University of Electro-Communications (JP), Tokyo University of Agriculture and Technology (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 36%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.