Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther

Objective: The anteroposterior (AP) pelvic X-ray is commonly used for assessing conditions affecting the bony pelvis. The objective of this study was to develop new pelvic X-ray assessment software (CalculOrther) to assess AP pelvic X-rays and evaluate its reliability. Methods: CalculOrther was developed in 4 stages. Initially, a dataset comprising pelvic X-rays was generated. During the second stage, the convolutional neural network model was trained to identify anatomical landmarks in the pelvic X-ray images. The Hough transform was used to locate the circle and center of the femoral head in the third stage. The border pixels were generated using mathematical morphological processes, and the requisite angles were measured in the fourth stage. Then manual measurements and the software developed were analyzed with Pearson’s correlation and intraobserver and interobserver correlation coefficients. Subsequently, the mean error and the root mean square error (RMSE) were acquired. Results: The Pearson’s correlation coefficients varied from 0.84 to 0.99 (P < .001). The interobserver and intraobserver correlation coefficients ranged from 0.77 to 0.99 and from 0.75 to 0.94, respectively. The RMSE ranged from 0.31 to 4.38 and the mean error from 0.05 to 2.86. The mean duration for manual measurements was 230 (177-284) seconds and 215 (160-255) seconds, respectively. The software required an average time of 3.18 (2.95-3.52) seconds to make the same measurements. Conclusion: Regarding femoroacetabular impingement and hip dysplasia, artificial intelligence can analyze pelvic radiographs and generate equally accurate results within a shorter duration compared to traditional measuring methods. Cite this article as: Yilmaz A, Selcuk T, Aksoy T, Atilla B. Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthop Traumatol Turc., 2026; 60(1), 0268, doi: 10.5152/j.aott.2026.25268

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica et Traumatologica Turcica
Published
2026-02-26
DOI
https://doi.org/10.5152/j.aott.2026.25268
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther

Bülent Atilla, Turab Selçuk, Abdurrahman Yılmaz, Taha Aksoy
Acta Orthopaedica et Traumatologica Turcica
Hip disorders and treatments
article

Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther

Bülent Atilla, Turab Selçuk, Abdurrahman Yılmaz, Taha Aksoy
article en

Abstract

Objective: The anteroposterior (AP) pelvic X-ray is commonly used for assessing conditions affecting the bony pelvis. The objective of this study was to develop new pelvic X-ray assessment software (CalculOrther) to assess AP pelvic X-rays and evaluate its reliability. Methods: CalculOrther was developed in 4 stages. Initially, a dataset comprising pelvic X-rays was generated. During the second stage, the convolutional neural network model was trained to identify anatomical landmarks in the pelvic X-ray images. The Hough transform was used to locate the circle and center of the femoral head in the third stage. The border pixels were generated using mathematical morphological processes, and the requisite angles were measured in the fourth stage. Then manual measurements and the software developed were analyzed with Pearson’s correlation and intraobserver and interobserver correlation coefficients. Subsequently, the mean error and the root mean square error (RMSE) were acquired. Results: The Pearson’s correlation coefficients varied from 0.84 to 0.99 (P < .001). The interobserver and intraobserver correlation coefficients ranged from 0.77 to 0.99 and from 0.75 to 0.94, respectively. The RMSE ranged from 0.31 to 4.38 and the mean error from 0.05 to 2.86. The mean duration for manual measurements was 230 (177-284) seconds and 215 (160-255) seconds, respectively. The software required an average time of 3.18 (2.95-3.52) seconds to make the same measurements. Conclusion: Regarding femoroacetabular impingement and hip dysplasia, artificial intelligence can analyze pelvic radiographs and generate equally accurate results within a shorter duration compared to traditional measuring methods. Cite this article as: Yilmaz A, Selcuk T, Aksoy T, Atilla B. Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthop Traumatol Turc., 2026; 60(1), 0268, doi: 10.5152/j.aott.2026.25268

Acta Orthopaedica et Traumatologica TurcicaVol. 60(1)
University of Miami (US), Kahramanmaraş Sütçü İmam University (TR), Hacettepe University (TR)
Openalex Percentile: Top 34%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.