Glutaraldehyde-Crosslinked Bovine Serum Albumin Hydrogels for Efficient Cu2+, Ni2+, and Co2+ Removal from Water

Heavy metal contamination remains a critical threat to water quality, particularly in effluents associated with industrial activities such as electroplating. This study presents an exploratory proof of concept for a simplified and low-requirement method to fabricate bovine serum albumin (BSA) hydrogels crosslinked with glutaraldehyde (GA) as protein-based adsorbents for Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Co<sup>2+</sup> removal. Hydrogel slabs were prepared using BSA concentrations of 20% and 25% (<i>w</i>/<i>v</i>) and GA in the 0.6-1.0% (<i>v</i>/<i>v</i>) range, with formulation adjustments guided by handling and aqueous stability. Swelling behavior was monitored for 23 days, and 0.9% (<i>v</i>/<i>v</i>) GA was selected to balance network expansion with hydrogel consistency. FT-IR confirmed preservation of protein functional groups in the crosslinked network, and TGA/DTG demonstrated multi-step thermal behavior consistent with hydrated protein matrices and a stabilizing effect of increased GA content. Metal removal tests at 50-100 ppm (Cu<sup>2+</sup>, Ni<sup>2+</sup>) and 70-100 ppm (Co<sup>2+</sup>) showed rapid removal approaching equilibrium within the first hours and improved performance at higher BSA content, achieving maximum removal percentages of 99.258% for Cu<sup>2+</sup>, 80.733% for Ni<sup>2+</sup>, and 76.070% for Co<sup>2+</sup>. Adsorption behaviors for Cu<sup>2+</sup> and Co<sup>2+</sup> aligned with the Langmuir model, while Ni<sup>2+</sup> was better described by the Freundlich model. Although the scope is intentionally preliminary and limited to controlled synthetic systems, these results support GA-crosslinked BSA hydrogels as promising, easily fabricated adsorbents and establish a foundation for future studies on broader ion selectivity, competitive adsorption, and adsorption-desorption performance.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-03-04
DOI
https://doi.org/10.3390/polym18050633
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glutaraldehyde-Crosslinked Bovine Serum Albumin Hydrogels for Efficient Cu2+, Ni2+, and Co2+ Removal from Water

Giselle Carolina Barón-Gualdrón, Angie Méndez-Bautista, Viviana Güiza-Argüello, Dayana Lancheros-Ayala
Polymers
Adsorption and biosorption for pollutant removal
article

Glutaraldehyde-Crosslinked Bovine Serum Albumin Hydrogels for Efficient Cu2+, Ni2+, and Co2+ Removal from Water

Giselle Carolina Barón-Gualdrón, Angie Méndez-Bautista, Viviana Güiza-Argüello, Dayana Lancheros-Ayala
article en

Abstract

Heavy metal contamination remains a critical threat to water quality, particularly in effluents associated with industrial activities such as electroplating. This study presents an exploratory proof of concept for a simplified and low-requirement method to fabricate bovine serum albumin (BSA) hydrogels crosslinked with glutaraldehyde (GA) as protein-based adsorbents for Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Co<sup>2+</sup> removal. Hydrogel slabs were prepared using BSA concentrations of 20% and 25% (<i>w</i>/<i>v</i>) and GA in the 0.6-1.0% (<i>v</i>/<i>v</i>) range, with formulation adjustments guided by handling and aqueous stability. Swelling behavior was monitored for 23 days, and 0.9% (<i>v</i>/<i>v</i>) GA was selected to balance network expansion with hydrogel consistency. FT-IR confirmed preservation of protein functional groups in the crosslinked network, and TGA/DTG demonstrated multi-step thermal behavior consistent with hydrated protein matrices and a stabilizing effect of increased GA content. Metal removal tests at 50-100 ppm (Cu<sup>2+</sup>, Ni<sup>2+</sup>) and 70-100 ppm (Co<sup>2+</sup>) showed rapid removal approaching equilibrium within the first hours and improved performance at higher BSA content, achieving maximum removal percentages of 99.258% for Cu<sup>2+</sup>, 80.733% for Ni<sup>2+</sup>, and 76.070% for Co<sup>2+</sup>. Adsorption behaviors for Cu<sup>2+</sup> and Co<sup>2+</sup> aligned with the Langmuir model, while Ni<sup>2+</sup> was better described by the Freundlich model. Although the scope is intentionally preliminary and limited to controlled synthetic systems, these results support GA-crosslinked BSA hydrogels as promising, easily fabricated adsorbents and establish a foundation for future studies on broader ion selectivity, competitive adsorption, and adsorption-desorption performance.

PolymersVol. 18(5)
Universidad Industrial de Santander (CO)
Universidad Industrial de Santander, Vicerrectoría de Investigación y Extensión, Universidad Industrial de Santander
Clean water and sanitation
Openalex Percentile: Top 39%
Adsorption and biosorption for pollutant removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.