PIC Model of a Relativistic Two-Cavity Reflex Klystron with a Magnetic Mirror

A concept and design of a relativistic two-cavity reflex klystron with a magnetic mirror has been proposed. A 2.5D particle-in-cell (PIC) computer model of a relativistic two-cavity reflex klystron with a magnetic mirror has been created on the basis of the KARAT PIC code. The model takes into account the supply of an external microwave from the master oscillator and allows self-consistent calculation of the electron dynamics and the output characteristics of the klystron. Comparative modeling of a relativistic two-cavity reflex klystron with a magnetic mirror and a relativistic two-cavity transit klystron without a magnetic mirror has been performed. It has been shown that the spectral characteristics of both klystrons are close to each other. The output power of the reflex and transit klystrons has been compared. It has been found that the output power of the reflex klystron is approximately 1.4 times greater than that of the transit klystron. The effect of the magnetic mirror position on the value of the generated microwave power of the reflection klystron has been studied.

Authors

Institutions

Publication Details

Journal
Physics of Atomic Nuclei
Published
2025-12-01
DOI
https://doi.org/10.1134/s1063778825100072
Primary Topic
Geophysics and Sensor Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PIC Model of a Relativistic Two-Cavity Reflex Klystron with a Magnetic Mirror

H. N. Kolesov, A. E. Dubinov
Physics of Atomic Nuclei
Geophysics and Sensor Technology
article

PIC Model of a Relativistic Two-Cavity Reflex Klystron with a Magnetic Mirror

H. N. Kolesov, A. E. Dubinov
article en

Abstract

A concept and design of a relativistic two-cavity reflex klystron with a magnetic mirror has been proposed. A 2.5D particle-in-cell (PIC) computer model of a relativistic two-cavity reflex klystron with a magnetic mirror has been created on the basis of the KARAT PIC code. The model takes into account the supply of an external microwave from the master oscillator and allows self-consistent calculation of the electron dynamics and the output characteristics of the klystron. Comparative modeling of a relativistic two-cavity reflex klystron with a magnetic mirror and a relativistic two-cavity transit klystron without a magnetic mirror has been performed. It has been shown that the spectral characteristics of both klystrons are close to each other. The output power of the reflex and transit klystrons has been compared. It has been found that the output power of the reflex klystron is approximately 1.4 times greater than that of the transit klystron. The effect of the magnetic mirror position on the value of the generated microwave power of the reflection klystron has been studied.

Physics of Atomic NucleiVol. 88(12)
Moscow Institute of Physics and Technology (RU), All-Russian Scientific Research Institute of Technical Physics (RU), Sarov Institute of Physics and Technology (RU), National Research Nuclear University MEPhI (RU)
Affordable and clean energy
Openalex Percentile: Top 29%
Geophysics and Sensor Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.