Equipment for Measuring the Kick Strength of the Extracted Bunch into the Aperture of the Septum Magnet SM24 of the U-70 Аccelerator
A prototype of equipment for measuring the radial position of a selected bunch in the aperture of the septum magnet SM24 has been created at IHEP. It is required for fast beam extraction from the U-70 synchrotron. Double measurement immediately before and at the moment of extraction allows us to determine the bunch kick strength into the septum aperture with a RMS error of no worse than 0.5 mm. In this article, the equipment is reviewed and the results of testing in real conditions are presented.
Authors
- I. V. Ivanova
- E. A. Syshchikov
- V. I. Terekhov
Institutions
- Kurchatov Institute (RU)
Publication Details
- Journal
- Physics of Atomic Nuclei
- Published
- 2025-12-01
- DOI
- https://doi.org/10.1134/s1063778825100412
- Primary Topic
- Superconducting Materials and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00