Comparative Exergoeconomic Analysis of Three Vapour-Compression Refrigeration System Configurations

Vapour-compression refrigeration and cooling systems represent a significant share of global electricity consumption, being estimated to account for approximately 10% to 20% of the worldwide electricity demand, which highlights their critical impact on energy efficiency and sustainability. In this context, improving the thermodynamic and exergoeconomic performance of refrigeration cycles, as well as the appropriate selection of the refrigerant, has become a key research priority. Therefore, this work aims to comparatively evaluate the energy, exergy, exergy cost, and exergoeconomic performance of three vapour-compression refrigeration cycle configurations: a simple cycle, a two-stage cycle with a flash tank, and a two-stage cycle with a flash tank and a mixing chamber. Six refrigerants (R134a, R600a, R290, R1234yf, R1234ze (E), and R717) were analysed under evaporation temperatures of 228–238 K and condensation temperatures of 298–308 K. The performance evaluation was carried out using the Fuel–Product–Residue (FPR) methodology, considering the coefficient of performance (COP), exergy efficiency, system irreversibilities, and exergy and exergoeconomic costs. The results indicate that the incorporation of the mixing chamber increases the COP by up to 7% and the exergy efficiency by up to 6% compared to the simple cycle, while reducing exergoeconomic costs by up to 10% for the most favourable refrigerants. Among the working fluids analysed, R600a exhibits the best overall performance (COP up to 4.3 and an exergy efficiency of 33%), followed by R290 and R717, whereas R1234yf shows the lowest efficiencies (COP ≈ 3.7 and exergy efficiency ≈ 28%) and the highest exergoeconomic costs. These findings demonstrate that the design of vapour-compression refrigeration systems should involve the joint selection of the cycle configuration and the refrigerant based on integrated energy, exergy, and exergoeconomic criteria. Overall, the results highlight that both the refrigerant and the cycle configuration must be selected simultaneously, considering energy, exergy, and exergoeconomic criteria, to achieve more efficient and sustainable industrial applications.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-03-04
DOI
https://doi.org/10.3390/app16052483
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Exergoeconomic Analysis of Three Vapour-Compression Refrigeration System Configurations

Raúl Lugo Leyte, Martín Salazar Pereyra, Sergio Castro Hernández, Alejandro Torres-Aldaco et al.
Applied Sciences
Refrigeration and Air Conditioning Technologies
article

Comparative Exergoeconomic Analysis of Three Vapour-Compression Refrigeration System Configurations

Raúl Lugo Leyte, Martín Salazar Pereyra, Sergio Castro Hernández, Alejandro Torres-Aldaco, Wenceslao C. Bonilla-Blancas, Helen D. Lugo-Méndez
article en

Abstract

Vapour-compression refrigeration and cooling systems represent a significant share of global electricity consumption, being estimated to account for approximately 10% to 20% of the worldwide electricity demand, which highlights their critical impact on energy efficiency and sustainability. In this context, improving the thermodynamic and exergoeconomic performance of refrigeration cycles, as well as the appropriate selection of the refrigerant, has become a key research priority. Therefore, this work aims to comparatively evaluate the energy, exergy, exergy cost, and exergoeconomic performance of three vapour-compression refrigeration cycle configurations: a simple cycle, a two-stage cycle with a flash tank, and a two-stage cycle with a flash tank and a mixing chamber. Six refrigerants (R134a, R600a, R290, R1234yf, R1234ze (E), and R717) were analysed under evaporation temperatures of 228–238 K and condensation temperatures of 298–308 K. The performance evaluation was carried out using the Fuel–Product–Residue (FPR) methodology, considering the coefficient of performance (COP), exergy efficiency, system irreversibilities, and exergy and exergoeconomic costs. The results indicate that the incorporation of the mixing chamber increases the COP by up to 7% and the exergy efficiency by up to 6% compared to the simple cycle, while reducing exergoeconomic costs by up to 10% for the most favourable refrigerants. Among the working fluids analysed, R600a exhibits the best overall performance (COP up to 4.3 and an exergy efficiency of 33%), followed by R290 and R717, whereas R1234yf shows the lowest efficiencies (COP ≈ 3.7 and exergy efficiency ≈ 28%) and the highest exergoeconomic costs. These findings demonstrate that the design of vapour-compression refrigeration systems should involve the joint selection of the cycle configuration and the refrigerant based on integrated energy, exergy, and exergoeconomic criteria. Overall, the results highlight that both the refrigerant and the cycle configuration must be selected simultaneously, considering energy, exergy, and exergoeconomic criteria, to achieve more efficient and sustainable industrial applications.

Applied SciencesVol. 16(5)
Universidad Autónoma Metropolitana (MX), Universidad de Ecatepec (MX)
Consejo Mexiquense de Ciencia y Tecnología
Affordable and clean energy
Openalex Percentile: Top 37%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.