Compact trace gas sensing via single-cavity balanced-detection interferometric cavity-assisted photothermal spectroscopy

• New balanced detection architecture for photothermal gas sensing, featuring: a reduced system complexity by utilizing a single 1-mm air-spaced Fabry-Perot interferometer, an improved signal-to-noise ratio by a factor of 18, a gas cell having a sample probe value of only 1.8 mL. • Robust sensing scheme: Refractive index changes which are induced by a mid-infrared excitation laser are monitored by a near-infrared probe laser intersecting the excitation beam in transverse configuration. • CO gas sensing achieving a minimum detection limit of 2 ppbv, which corresponds to a NNEA of 7.4 x 10 −9 cm −1 W Hz −1/2 . • Investigation of the influence of a varying water vapor concentration on the molecular relaxation process of CO at a modulation frequency of ∼ 300 Hz. This work reports on the implementation of an alternative balanced-detection scheme to the ICAPS sensing method employing solely a single cavity. The new concept was realized by simultaneous detection of the interferometer’s reflectance and transmission. The use of only one cavity significantly reduces the system’s complexity in a balanced configuration by simplifying the detection architecture. Additionally, it increases the sensor’s sensitivity by noise cancellation and an improvement of the detectable signal up to a factor of 2. The set-up employed an optical cavity with a mirror spacing of 1 mm. A mid-infrared laser served as excitation source to induce refractive index changes in the sample, and a near-infrared laser served as probe source to monitor the photo-induced variations. The sensor’s metrological figures of merit were investigated by detection of CO. Moreover, the influence of varying water vapor concentration on the molecular relaxation of CO and thus the monitored photothermal signal employing a modulation frequency of ∼ 300 Hz was investigated. For the targeted absorption band centered at 2179.77 cm −1 a 1σ minimum detection limit of 2 ppbv was achieved using an integration time of 1 s. This result corresponds to a normalized noise equivalent absorption of 7.4 × 10 −9 cm −1 W Hz −1/2 .

Authors

Institutions

Publication Details

Journal
Infrared Physics & Technology
Published
2026-03-05
DOI
https://doi.org/10.1016/j.infrared.2026.106497
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compact trace gas sensing via single-cavity balanced-detection interferometric cavity-assisted photothermal spectroscopy

Johannes P. Waclawek, Harald Moser, Bernhard Lendl, Ufuk Yilmaz
Infrared Physics & Technology
Spectroscopy and Laser Applications
article

Compact trace gas sensing via single-cavity balanced-detection interferometric cavity-assisted photothermal spectroscopy

Johannes P. Waclawek, Harald Moser, Bernhard Lendl, Ufuk Yilmaz
article en

Abstract

• New balanced detection architecture for photothermal gas sensing, featuring: a reduced system complexity by utilizing a single 1-mm air-spaced Fabry-Perot interferometer, an improved signal-to-noise ratio by a factor of 18, a gas cell having a sample probe value of only 1.8 mL. • Robust sensing scheme: Refractive index changes which are induced by a mid-infrared excitation laser are monitored by a near-infrared probe laser intersecting the excitation beam in transverse configuration. • CO gas sensing achieving a minimum detection limit of 2 ppbv, which corresponds to a NNEA of 7.4 x 10 −9 cm −1 W Hz −1/2 . • Investigation of the influence of a varying water vapor concentration on the molecular relaxation process of CO at a modulation frequency of ∼ 300 Hz. This work reports on the implementation of an alternative balanced-detection scheme to the ICAPS sensing method employing solely a single cavity. The new concept was realized by simultaneous detection of the interferometer’s reflectance and transmission. The use of only one cavity significantly reduces the system’s complexity in a balanced configuration by simplifying the detection architecture. Additionally, it increases the sensor’s sensitivity by noise cancellation and an improvement of the detectable signal up to a factor of 2. The set-up employed an optical cavity with a mirror spacing of 1 mm. A mid-infrared laser served as excitation source to induce refractive index changes in the sample, and a near-infrared laser served as probe source to monitor the photo-induced variations. The sensor’s metrological figures of merit were investigated by detection of CO. Moreover, the influence of varying water vapor concentration on the molecular relaxation of CO and thus the monitored photothermal signal employing a modulation frequency of ∼ 300 Hz was investigated. For the targeted absorption band centered at 2179.77 cm −1 a 1σ minimum detection limit of 2 ppbv was achieved using an integration time of 1 s. This result corresponds to a normalized noise equivalent absorption of 7.4 × 10 −9 cm −1 W Hz −1/2 .

Infrared Physics & TechnologyVol. 155
TU Wien (AT)
Affordable and clean energy
Openalex Percentile: Top 37%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines