Assessment of arrhythmias in healthy cats using 24-hour Holter monitoring: a cross-sectional study

The objective of this study is to investigate heart rate variables and evaluate the prevalence and characteristics of ventricular premature complexes (VPCs) and supraventricular premature complexes (SPCs) in healthy cats, using 24-hour Holter monitoring in the home environment. Thirty-five healthy, client-owned cats were enrolled and divided into two groups: Group 1 included cats aged < 7 years, and Group 2 included cats aged 7 years and older. Clinical examination, blood pressure measurement, total thyroxine levels, echocardiographic assessment and 24-hour Holter monitoring were performed for each cat. The average minimum (HRmin), mean (HRmean), and maximum heart rate (HRmax) were 103 ± 16.1 bpm, 151 ± 20.2 bpm, and 244 ± 22.6 bpm, respectively. Only HRmin differed between age groups (P = 0.027). Although the percentage of cats with VPCs was similar across groups (75% in Group 1 vs. 91% in Group 2, P = 0.391), older individuals had significantly more VPCs (median 13 vs. 3, P = 0.020), and a higher prevalence of complex arrhythmias (55% vs. 12%, P = 0.014). Older age (P = 0.009), male sex (P = 0.026) and lower body weight (P = 0.049) were significant predictors of the occurrence of VPCs, as well as daytime vs. nighttime (P = 0.013). The number of SPCs was similar in both groups (median and range- 0.5 [0–13] vs. 1 [0–31], P = 0.299). A small sample size, unevenly distributed between age groups; uneven distribution of cat breeds; analysis of Holter data was made by a single operator; first period of the recording was not excluded from the analysis. Ventricular arrhythmias are common in healthy cats, and their prevalence and complexity increase with age. Age, sex and weight are significant predictors of the occurrence of VPCs, and VPCs tend to appear more during the day.

Authors

Institutions

Publication Details

Journal
BMC Veterinary Research
Published
2026-03-04
DOI
https://doi.org/10.1186/s12917-026-05364-4
Primary Topic
Cardiovascular Conditions and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of arrhythmias in healthy cats using 24-hour Holter monitoring: a cross-sectional study

Raluca Murariu, Iuliu Călin Scurtu, Alexandra Cofaru
BMC Veterinary Research
Cardiovascular Conditions and Treatments
article

Assessment of arrhythmias in healthy cats using 24-hour Holter monitoring: a cross-sectional study

Raluca Murariu, Iuliu Călin Scurtu, Alexandra Cofaru
article en

Abstract

The objective of this study is to investigate heart rate variables and evaluate the prevalence and characteristics of ventricular premature complexes (VPCs) and supraventricular premature complexes (SPCs) in healthy cats, using 24-hour Holter monitoring in the home environment. Thirty-five healthy, client-owned cats were enrolled and divided into two groups: Group 1 included cats aged < 7 years, and Group 2 included cats aged 7 years and older. Clinical examination, blood pressure measurement, total thyroxine levels, echocardiographic assessment and 24-hour Holter monitoring were performed for each cat. The average minimum (HRmin), mean (HRmean), and maximum heart rate (HRmax) were 103 ± 16.1 bpm, 151 ± 20.2 bpm, and 244 ± 22.6 bpm, respectively. Only HRmin differed between age groups (P = 0.027). Although the percentage of cats with VPCs was similar across groups (75% in Group 1 vs. 91% in Group 2, P = 0.391), older individuals had significantly more VPCs (median 13 vs. 3, P = 0.020), and a higher prevalence of complex arrhythmias (55% vs. 12%, P = 0.014). Older age (P = 0.009), male sex (P = 0.026) and lower body weight (P = 0.049) were significant predictors of the occurrence of VPCs, as well as daytime vs. nighttime (P = 0.013). The number of SPCs was similar in both groups (median and range- 0.5 [0–13] vs. 1 [0–31], P = 0.299). A small sample size, unevenly distributed between age groups; uneven distribution of cat breeds; analysis of Holter data was made by a single operator; first period of the recording was not excluded from the analysis. Ventricular arrhythmias are common in healthy cats, and their prevalence and complexity increase with age. Age, sex and weight are significant predictors of the occurrence of VPCs, and VPCs tend to appear more during the day.

BMC Veterinary Research
University of Agricultural Sciences and Veterinary Medicine of Cluj-Napoca (RO)
Good health and well-being
Openalex Percentile: Top 36%
Cardiovascular Conditions and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of arrhythmias in healthy cats using 24-hour Holter monitoring: a cross-sectional study — Raluca Murariu, Iuliu Călin Scurtu, et al. · BMC Veterinary Research (2026) | TGRS Research Map | TGRS