Automated fluence optimization in breast cancer radiotherapy: balancing dosimetric quality, organ-at-risk sparing, and workflow efficiency

In this study, we evaluated the effectiveness of EZFluence (EZF), an automated fluence optimization tool, in planning breast cancer radiotherapy by comparing its dosimetric performance with that of three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT). Specifically, we aimed to determine whether EZF can enhance target coverage, minimize dose to organs at risk, and improve planning efficiency. This retrospective analysis included 35 patients who received whole-breast irradiation for left-sided breast cancer. Treatment plans were generated using 3D-CRT, IMRT, VMAT, and EZF-based forward-planned field-in-field techniques. Dosimetric parameters, including planning target volume coverage, cardiac exposure, left anterior descending artery dose, lung dose, and contralateral tissue dose, were analyzed. Planning efficiency was assessed by comparing the monitor units and planning time. EZF demonstrated significantly superior dose homogeneity and a lower delivered maximum dose compared with 3D-CRT and IMRT. Although VMAT provided the highest planning target volume V95, EZF maintained comparable target coverage with significantly reduced high-dose regions. Additionally, EZF achieved a lower mean heart dose compared with 3D-CRT and IMRT. While VMAT offered superior high-dose cardiac sparing, EZF minimized low-dose cardiac spread and significantly reduced the mean lung dose and low-dose volumes of the left lung compared with IMRT and VMAT. The mean doses to the contralateral breast with 3D-CRT and EZF were less than 1 Gy, whereas those when using IMRT and VMAT exceeded 1 Gy. Regarding efficiency, EZF required fewer monitor units than did IMRT and VMAT, and its automated planning process reduced inter-planner variability. EZF demonstrated significant potential as an innovative approach in breast cancer radiotherapy, providing comparable target coverage with enhanced sparing of organs at risk and without unnecessary contralateral dose. Its automated fluence optimization enhanced planning efficiency by simplifying planning and reducing variability. These findings support the integration of EZF into routine clinical practice to optimize radiotherapy delivery.

Authors

Institutions

Publication Details

Journal
Radiation Oncology
Published
2026-03-04
DOI
https://doi.org/10.1186/s13014-026-02815-y
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated fluence optimization in breast cancer radiotherapy: balancing dosimetric quality, organ-at-risk sparing, and workflow efficiency

Han-Back Shin, KiHoon Sung, Young Eun Choi
Radiation Oncology
Advanced Radiotherapy Techniques
article

Automated fluence optimization in breast cancer radiotherapy: balancing dosimetric quality, organ-at-risk sparing, and workflow efficiency

Han-Back Shin, KiHoon Sung, Young Eun Choi
article en

Abstract

In this study, we evaluated the effectiveness of EZFluence (EZF), an automated fluence optimization tool, in planning breast cancer radiotherapy by comparing its dosimetric performance with that of three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT). Specifically, we aimed to determine whether EZF can enhance target coverage, minimize dose to organs at risk, and improve planning efficiency. This retrospective analysis included 35 patients who received whole-breast irradiation for left-sided breast cancer. Treatment plans were generated using 3D-CRT, IMRT, VMAT, and EZF-based forward-planned field-in-field techniques. Dosimetric parameters, including planning target volume coverage, cardiac exposure, left anterior descending artery dose, lung dose, and contralateral tissue dose, were analyzed. Planning efficiency was assessed by comparing the monitor units and planning time. EZF demonstrated significantly superior dose homogeneity and a lower delivered maximum dose compared with 3D-CRT and IMRT. Although VMAT provided the highest planning target volume V95, EZF maintained comparable target coverage with significantly reduced high-dose regions. Additionally, EZF achieved a lower mean heart dose compared with 3D-CRT and IMRT. While VMAT offered superior high-dose cardiac sparing, EZF minimized low-dose cardiac spread and significantly reduced the mean lung dose and low-dose volumes of the left lung compared with IMRT and VMAT. The mean doses to the contralateral breast with 3D-CRT and EZF were less than 1 Gy, whereas those when using IMRT and VMAT exceeded 1 Gy. Regarding efficiency, EZF required fewer monitor units than did IMRT and VMAT, and its automated planning process reduced inter-planner variability. EZF demonstrated significant potential as an innovative approach in breast cancer radiotherapy, providing comparable target coverage with enhanced sparing of organs at risk and without unnecessary contralateral dose. Its automated fluence optimization enhanced planning efficiency by simplifying planning and reducing variability. These findings support the integration of EZF into routine clinical practice to optimize radiotherapy delivery.

Radiation Oncology
Gachon University (KR), Gachon University Gil Medical Center (KR), Gachon University Gil Hospital (KR)
Openalex Percentile: Top 30%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.