Tailoring the microstructure of biodegradable Zn-Cu-Li wires via thermo-mechanical processing towards high-performance surgical staples

Although biodegradable Zn alloy fine wires are promising for staples, most exhibit inadequate mechanical properties, and current studies remain preliminary. In this work, Zn-2Cu-0.8Li (wt%) alloy fine wires (0.22 mm) for staples with outstanding mechanical properties were fabricated via hot extrusion, multi-pass drawing at room temperature and annealing. The microstructure, property evolutions and application feasibility for staples were systematically studied. The drawing process induces dramatic elongation of the <i>β</i>-LiZn<sub>4</sub> matrix, accompanied by dynamic recovery (DRV) and continuous dynamic recrystallization (CDRX). The low-angle grain boundary fractions significantly increase and the average grain sizes dramatically decrease. The <i>η</i>-Zn distributes as fine equiaxed grain bands due to DRX. The tensile yield strength (TYS) and ultimate tensile strength (UTS) increase from 376 MPa and 423 MPa to 596 MPa and 631 MPa, respectively, due to grain boundary (GB) and texture strengthening. Meanwhile, the deformability remains good with fracture elongation (EL) of 25.4% owing to DRV, CDRX and the presence of <i>η</i>-Zn. The wires annealed at 120 °C for 1 h show optimal mechanical properties (TYS: 492 MPa, UTS: 537 MPa and EL: 44.2%). The wires exhibit uniform degradation mode with a higher degradation rate of 327 μm∙year<sup>-1</sup> than as-extruded wires due to increased GB densities. The fabricated staples show an ultimate tensile force of 1.86 N comparable to Ti staples. They can achieve satisfactory anastomosis of beagle gastric tissue, and show appropriate degradation properties in vitro and in vivo. These findings indicate that Zn-2Cu-0.8Li fine wires and staples are promising for clinical applications.

Authors

Institutions

Publication Details

Journal
Bioactive Materials
Published
2026-03-04
DOI
https://doi.org/10.1016/j.bioactmat.2026.02.055
Primary Topic
Microstructure and mechanical properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tailoring the microstructure of biodegradable Zn-Cu-Li wires via thermo-mechanical processing towards high-performance surgical staples

Zilong Wang, Guangyin Yuan, Hua Huang, Wenhao Zhou et al.
Bioactive Materials
Microstructure and mechanical properties
article

Tailoring the microstructure of biodegradable Zn-Cu-Li wires via thermo-mechanical processing towards high-performance surgical staples

Zilong Wang, Guangyin Yuan, Hua Huang, Wenhao Zhou, Chun Chen, Zhiqiang Gao, Jialin Niu, Jimiao Jiang, Cheng Liu, Xiyuan Zhang
article en

Abstract

Although biodegradable Zn alloy fine wires are promising for staples, most exhibit inadequate mechanical properties, and current studies remain preliminary. In this work, Zn-2Cu-0.8Li (wt%) alloy fine wires (0.22 mm) for staples with outstanding mechanical properties were fabricated via hot extrusion, multi-pass drawing at room temperature and annealing. The microstructure, property evolutions and application feasibility for staples were systematically studied. The drawing process induces dramatic elongation of the <i>β</i>-LiZn<sub>4</sub> matrix, accompanied by dynamic recovery (DRV) and continuous dynamic recrystallization (CDRX). The low-angle grain boundary fractions significantly increase and the average grain sizes dramatically decrease. The <i>η</i>-Zn distributes as fine equiaxed grain bands due to DRX. The tensile yield strength (TYS) and ultimate tensile strength (UTS) increase from 376 MPa and 423 MPa to 596 MPa and 631 MPa, respectively, due to grain boundary (GB) and texture strengthening. Meanwhile, the deformability remains good with fracture elongation (EL) of 25.4% owing to DRV, CDRX and the presence of <i>η</i>-Zn. The wires annealed at 120 °C for 1 h show optimal mechanical properties (TYS: 492 MPa, UTS: 537 MPa and EL: 44.2%). The wires exhibit uniform degradation mode with a higher degradation rate of 327 μm∙year<sup>-1</sup> than as-extruded wires due to increased GB densities. The fabricated staples show an ultimate tensile force of 1.86 N comparable to Ti staples. They can achieve satisfactory anastomosis of beagle gastric tissue, and show appropriate degradation properties in vitro and in vivo. These findings indicate that Zn-2Cu-0.8Li fine wires and staples are promising for clinical applications.

Bioactive MaterialsVol. 61
Shanghai Jiao Tong University (CN), Dongguan University of Technology (CN), Northwest Institute For Non-Ferrous Metal Research (CN), Suzhou Research Institute (CN)
Openalex Percentile: Top 37%
Microstructure and mechanical properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.