Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete

This research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obtained at 1.25% fiber content. The addition of steel fibers enhanced column performance, and energy absorption improved by up to 27% compared to specimens without steel fibers. Experimental validation demonstrated improved accuracy in terms of behavior and predicted models. The conclusions of this work provide valuable design insights enabling the adaptation of the overall column system under complex loading scenarios.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-03-03
DOI
https://doi.org/10.3390/buildings16050997
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete

Mohanned Al Gharawi, Teghreed H. Ibrahim, Hussein K. Mohammad, Mohammed Riyadh Khalaf et al.
Buildings
Structural Load-Bearing Analysis
article

Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete

Mohanned Al Gharawi, Teghreed H. Ibrahim, Hussein K. Mohammad, Mohammed Riyadh Khalaf, Alaa Al-Mosawe, Abbas A. Allawi
article en

Abstract

This research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obtained at 1.25% fiber content. The addition of steel fibers enhanced column performance, and energy absorption improved by up to 27% compared to specimens without steel fibers. Experimental validation demonstrated improved accuracy in terms of behavior and predicted models. The conclusions of this work provide valuable design insights enabling the adaptation of the overall column system under complex loading scenarios.

BuildingsVol. 16(5)
University of Baghdad (IQ), Ministry of Higher Education and Scientific Research (IQ), Swinburne University of Technology (AU)
Affordable and clean energy
Openalex Percentile: Top 37%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete — Mohanned Al Gharawi, Teghreed H. Ibrahim, et al. · Buildings (2026) | TGRS Research Map | TGRS