Automatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume

<i>Aims</i>: Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views.<i>Methods</i>: Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines.<i>Results</i>: The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s.<i>Conclusions</i>: Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-03-03
DOI
https://doi.org/10.1088/2057-1976/ae4808
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume

Gakuto Aoyama, Zhexin Zhou, Kota Aoyagi, Yui Nozaki et al.
Biomedical Physics & Engineering Express
Advanced Radiotherapy Techniques
article

Automatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume

Gakuto Aoyama, Zhexin Zhou, Kota Aoyagi, Yui Nozaki, Masahiko Asami, Hong Yang, Yufei Li, Shinichiro Fujimoto, James V Chapman, Bing Han
article en

Abstract

<i>Aims</i>: Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views.<i>Methods</i>: Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines.<i>Results</i>: The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s.<i>Conclusions</i>: Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.

Biomedical Physics & Engineering ExpressVol. 12(2)
Canon (Japan) (JP), Juntendo University (JP), Mitsui Memorial Hospital (JP), Tochigi Medical Center (JP), Beijing Chaoyang Emergency Medical Center (CN)
Openalex Percentile: Top 31%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.