Spatiotemporal and Digital Electrochemiluminescence Imaging for Intelligent Quantitative Biosensing

Electrochemiluminescence (ECL) imaging has progressed from a sensitive-intensity-based detection method to a powerful analytical platform capable of resolving biological and chemical heterogeneity at the single-entity level. This review maps the evolution of ECL imaging along three major axes: (i) spatiotemporal resolution, enabled by advanced luminophores, confined and built-in coreactant pathways, nanozyme catalysis, and 3D emissive-layer control; (ii) digitalization, in which analog luminescence is converted into discrete, statistically robust events for ultrasensitive quantification; and (iii) intelligent analysis, where artificial intelligence enhances denoising, emitter localization, dynamic tracking, multiplexed decoding, and kinetic inference. Mechanistic innovations─such as nanoscale confinement, intramolecular coreactant design, in situ conversion of endogenous metabolites, and asymmetric nanostructures─provide brighter, more localized, and biocompatible emission sources. Parallel advances in materials (metal nanoclusters, quantum dots, perovskites, AIE luminogens, Janus particles), imaging platforms (SECL/PECL modes, super-resolution strategies, microfluidics, smartphone/Raspberry-Pi devices, and large-scale bipolar-electrode arrays), and digital/AI pipelines collectively enable the high-fidelity capture of dynamic processes from single molecules to complex 3D spheroids. Together, these developments establish a coherent spatiotemporal–digital–intelligent framework and position ECL imaging as a versatile, scalable, and excitation-free modality for next-generation biosensing, clinical diagnostics, drug screening, environmental monitoring, and functional material characterization.

Authors

Institutions

Publication Details

Journal
Chemical & Biomedical Imaging
Published
2026-03-03
DOI
https://doi.org/10.1021/cbmi.5c00257
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatiotemporal and Digital Electrochemiluminescence Imaging for Intelligent Quantitative Biosensing

Tadele Eticha, Yiran Guan, Yu Zheng, Jinwei Xiao et al.
Chemical & Biomedical Imaging
Advanced biosensing and bioanalysis techniques
article

Spatiotemporal and Digital Electrochemiluminescence Imaging for Intelligent Quantitative Biosensing

Tadele Eticha, Yiran Guan, Yu Zheng, Jinwei Xiao, Guobao Xu, Saman Hosseinkhani, Dejana Bešlić
article en

Abstract

Electrochemiluminescence (ECL) imaging has progressed from a sensitive-intensity-based detection method to a powerful analytical platform capable of resolving biological and chemical heterogeneity at the single-entity level. This review maps the evolution of ECL imaging along three major axes: (i) spatiotemporal resolution, enabled by advanced luminophores, confined and built-in coreactant pathways, nanozyme catalysis, and 3D emissive-layer control; (ii) digitalization, in which analog luminescence is converted into discrete, statistically robust events for ultrasensitive quantification; and (iii) intelligent analysis, where artificial intelligence enhances denoising, emitter localization, dynamic tracking, multiplexed decoding, and kinetic inference. Mechanistic innovations─such as nanoscale confinement, intramolecular coreactant design, in situ conversion of endogenous metabolites, and asymmetric nanostructures─provide brighter, more localized, and biocompatible emission sources. Parallel advances in materials (metal nanoclusters, quantum dots, perovskites, AIE luminogens, Janus particles), imaging platforms (SECL/PECL modes, super-resolution strategies, microfluidics, smartphone/Raspberry-Pi devices, and large-scale bipolar-electrode arrays), and digital/AI pipelines collectively enable the high-fidelity capture of dynamic processes from single molecules to complex 3D spheroids. Together, these developments establish a coherent spatiotemporal–digital–intelligent framework and position ECL imaging as a versatile, scalable, and excitation-free modality for next-generation biosensing, clinical diagnostics, drug screening, environmental monitoring, and functional material characterization.

Chemical & Biomedical Imaging
University of Science and Technology of China (CN), Tarbiat Modares University (IR), Chinese Academy of Sciences (CN), Changchun Institute of Applied Chemistry (CN), State Key Laboratory of Electroanalytical Chemistry
Openalex Percentile: Top 35%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.