Implantable and Stretchable Magnetoelectric Sensor for Motion-Assisted Wireless Signaling Using Biocompatible Piezoelectric Elastomer/Cobalt Ferrite Composites

Personal identification allows for confirmation of a certain person, which is widely used in security certification and financial payment. Current personal identification methods, including passwords, fingerprints, voices, and facial recognition, are all facing counterfeit risk. Implantable wireless communication technology holds promise to significantly improve the safety for personal identification; however, the stretchability, biocompatibility, and power consumption of implanted sensors still remain great challenges. This study developed an implantable and stretchable magnetoelectric sensor (ISMS) based on biocompatible piezo-elastomer (BPEA)/cobalt ferrite (CoFe<sub>2</sub>O<sub>4</sub>) composites for synchronous realization of personal identification and activity monitoring. The piezo-elastomer is synthesized with high piezoelectricity and stretchability, which is favorable to a compound with high magnetostrictive CoFe<sub>2</sub>O<sub>4</sub>. The BPEA/CoFe<sub>2</sub>O<sub>4</sub> ISMS presents a high response to electromagnetic waves of 54.56 dB at 2.4 GHz and 44.88 dB at 5 GHz, respectively, to realize personal identification, while its piezoelectric function further improves the identified safety by response to specific activities. Meanwhile, the ISMS shows cyclic elongation over 200% to satisfy synchronous in vivo movement with skin tissue, while its high biocompatibility ensures biosafety for long-term in vivo use.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-03-02
DOI
https://doi.org/10.1021/acsami.5c22098
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implantable and Stretchable Magnetoelectric Sensor for Motion-Assisted Wireless Signaling Using Biocompatible Piezoelectric Elastomer/Cobalt Ferrite Composites

Yuan Yang, Qiming Wang, Chaoyi Zhang, Zhencheng Xiong et al.
ACS Applied Materials & Interfaces
Advanced Sensor and Energy Harvesting Materials
article

Implantable and Stretchable Magnetoelectric Sensor for Motion-Assisted Wireless Signaling Using Biocompatible Piezoelectric Elastomer/Cobalt Ferrite Composites

Yuan Yang, Qiming Wang, Chaoyi Zhang, Zhencheng Xiong, Yong Xiang, Xiaoran Hu, Zhao Wang
article en

Abstract

Personal identification allows for confirmation of a certain person, which is widely used in security certification and financial payment. Current personal identification methods, including passwords, fingerprints, voices, and facial recognition, are all facing counterfeit risk. Implantable wireless communication technology holds promise to significantly improve the safety for personal identification; however, the stretchability, biocompatibility, and power consumption of implanted sensors still remain great challenges. This study developed an implantable and stretchable magnetoelectric sensor (ISMS) based on biocompatible piezo-elastomer (BPEA)/cobalt ferrite (CoFe<sub>2</sub>O<sub>4</sub>) composites for synchronous realization of personal identification and activity monitoring. The piezo-elastomer is synthesized with high piezoelectricity and stretchability, which is favorable to a compound with high magnetostrictive CoFe<sub>2</sub>O<sub>4</sub>. The BPEA/CoFe<sub>2</sub>O<sub>4</sub> ISMS presents a high response to electromagnetic waves of 54.56 dB at 2.4 GHz and 44.88 dB at 5 GHz, respectively, to realize personal identification, while its piezoelectric function further improves the identified safety by response to specific activities. Meanwhile, the ISMS shows cyclic elongation over 200% to satisfy synchronous in vivo movement with skin tissue, while its high biocompatibility ensures biosafety for long-term in vivo use.

ACS Applied Materials & InterfacesVol. 18(10)
University of Electronic Science and Technology of China (CN), Peking University (CN), Sichuan University (CN), West China Medical Center of Sichuan University (CN), Flex (Mauritius) (MU), Peking University Third Hospital (CN), South China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 38%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.