Rational Design of Amperometric Sensor Based on Magnesium Oxide and Reduced Graphene Oxide Hybrid for Ultralow Detection of Cephalexin in Complex Biological Matrices

Cephalexin (CEX) is the first-generation β-lactam antibiotic drug used to treat urinary, respiratory, and skin infections. However, the overtherapeutic use of CEX necessitates its accurate and low-level monitoring in biological and clinical applications. In the current work, an amperometric electrochemical sensor based on a magnesium oxide/reduced graphene oxide (MgO/rGO) nanocomposite was successfully prepared for reliable and sensitive determination of CEX in biological samples. First, the MgO/rGO hybrid was comprehensively characterized. The XRD patterns revealed an excellent crystalline structure and an average crystallite size of 20.6 nm. The FTIR spectra manifested the disappearance of GO peaks and the emergence of MgO peaks, confirming the successful synthesis of MgO/rGO hybrid nanocomposite. The SEM images exhibited highly exfoliated GO sheets after incorporating MgO, offering a broad electroactive surface area, and the EDX images confirmed the elemental composition and uniform distribution of Mg and O within the rGO matrix. The electrochemical characterization of MgO/rGO-modified glassy carbon electrode (MgO/rGO/GCE) was carried out on cyclic voltammetry and electrochemical impedance spectroscopy, which revealed excellent redox response and charge-transfer kinetics. Under the optimal conditions, e.g., scan rate of 80 mV·s<sup>-1</sup>, PBS electrolyte (pH 3), and potential window from 0.4 to 1.8 V, the fabricated sensor exhibited a low limit of detection calculated as 1.3 nM. The prepared sensor detected CEX in human urine and serum samples with good recovery values, confirming its capability for real biological and clinical samples.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-03-03
DOI
https://doi.org/10.1021/acs.analchem.5c07739
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rational Design of Amperometric Sensor Based on Magnesium Oxide and Reduced Graphene Oxide Hybrid for Ultralow Detection of Cephalexin in Complex Biological Matrices

Saba Ali, Amber R. Solangi, Jamil A. Buledi, Iuliia Golovynska et al.
Analytical Chemistry
Electrochemical sensors and biosensors
article

Rational Design of Amperometric Sensor Based on Magnesium Oxide and Reduced Graphene Oxide Hybrid for Ultralow Detection of Cephalexin in Complex Biological Matrices

Saba Ali, Amber R. Solangi, Jamil A. Buledi, Iuliia Golovynska, Sergii Golovynskyi, Junle Qu
article en

Abstract

Cephalexin (CEX) is the first-generation β-lactam antibiotic drug used to treat urinary, respiratory, and skin infections. However, the overtherapeutic use of CEX necessitates its accurate and low-level monitoring in biological and clinical applications. In the current work, an amperometric electrochemical sensor based on a magnesium oxide/reduced graphene oxide (MgO/rGO) nanocomposite was successfully prepared for reliable and sensitive determination of CEX in biological samples. First, the MgO/rGO hybrid was comprehensively characterized. The XRD patterns revealed an excellent crystalline structure and an average crystallite size of 20.6 nm. The FTIR spectra manifested the disappearance of GO peaks and the emergence of MgO peaks, confirming the successful synthesis of MgO/rGO hybrid nanocomposite. The SEM images exhibited highly exfoliated GO sheets after incorporating MgO, offering a broad electroactive surface area, and the EDX images confirmed the elemental composition and uniform distribution of Mg and O within the rGO matrix. The electrochemical characterization of MgO/rGO-modified glassy carbon electrode (MgO/rGO/GCE) was carried out on cyclic voltammetry and electrochemical impedance spectroscopy, which revealed excellent redox response and charge-transfer kinetics. Under the optimal conditions, e.g., scan rate of 80 mV·s<sup>-1</sup>, PBS electrolyte (pH 3), and potential window from 0.4 to 1.8 V, the fabricated sensor exhibited a low limit of detection calculated as 1.3 nM. The prepared sensor detected CEX in human urine and serum samples with good recovery values, confirming its capability for real biological and clinical samples.

Analytical ChemistryVol. 98(10)
University of Sindh (PK), Shenzhen University (CN), Integrated Optoelectronics (Norway) (NO), National Centre of Excellence in Analytical Chemistry (PK)
Openalex Percentile: Top 37%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.