A robust microneedle-based electrochemical sensor for continuous in vivo monitoring of pH

Continuous monitoring of physiological pH is essential for disease diagnosis and health management, yet developing minimally invasive implantable sensors with adequate stability remains challenging. We developed a micro-electrochemical pH sensor fabricated on a flexible gold wire substrate modified with a platinum black and polyaniline nanocomposite. Through a two-step electrochemical deposition process, a porous platinum nanostructure was constructed to increase the electrochemically active surface area, providing a stable scaffold for the subsequent polyaniline coating. The resulting sensor displayed a linear response from pH 4 to 10 with a sensitivity of −45.2 mV/pH (R2 = 0.998) and intra-batch reproducibility with a coefficient of variation below 1.4%. Specificity tests confirmed negligible potential drift in the presence of common interfering ions. The sensor's practical applicability was validated in complex biological environments; in diluted serum, it maintained a stable baseline and responded rapidly to pH fluctuations, effectively resisting biofouling. In vivo experiments involving subcutaneous implantation in an anesthetized mouse successfully tracked continuous pH variations induced by chemical stimuli. After seven days in phosphate-buffered saline, the sensor retained 78.5% of its initial response. This work presents a robust, easily fabricated microsensor strategy promising for continuous in vivo monitoring of pH.

Authors

Publication Details

Journal
Electrochemistry Communications
Published
2026-03-04
DOI
https://doi.org/10.1016/j.elecom.2026.108141
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A robust microneedle-based electrochemical sensor for continuous in vivo monitoring of pH

Mingxing Yu, Tingting Lan, Tao Ming, Zhihong Wang et al.
Electrochemistry Communications
Advancements in Transdermal Drug Delivery
article

A robust microneedle-based electrochemical sensor for continuous in vivo monitoring of pH

Mingxing Yu, Tingting Lan, Tao Ming, Zhihong Wang, DeLing KONG, Chang Liu (35901), Yue He, Zhou Yu, Kaixuan Zhang, Junhao Wu, Zongfeng Jiang, Xindi Zhao, Xinyue Qu
article en

Abstract

Continuous monitoring of physiological pH is essential for disease diagnosis and health management, yet developing minimally invasive implantable sensors with adequate stability remains challenging. We developed a micro-electrochemical pH sensor fabricated on a flexible gold wire substrate modified with a platinum black and polyaniline nanocomposite. Through a two-step electrochemical deposition process, a porous platinum nanostructure was constructed to increase the electrochemically active surface area, providing a stable scaffold for the subsequent polyaniline coating. The resulting sensor displayed a linear response from pH 4 to 10 with a sensitivity of −45.2 mV/pH (R2 = 0.998) and intra-batch reproducibility with a coefficient of variation below 1.4%. Specificity tests confirmed negligible potential drift in the presence of common interfering ions. The sensor's practical applicability was validated in complex biological environments; in diluted serum, it maintained a stable baseline and responded rapidly to pH fluctuations, effectively resisting biofouling. In vivo experiments involving subcutaneous implantation in an anesthetized mouse successfully tracked continuous pH variations induced by chemical stimuli. After seven days in phosphate-buffered saline, the sensor retained 78.5% of its initial response. This work presents a robust, easily fabricated microsensor strategy promising for continuous in vivo monitoring of pH.

Electrochemistry CommunicationsVol. 186
Openalex Percentile: Top 35%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A robust microneedle-based electrochemical sensor for continuous in vivo monitoring of pH — Mingxing Yu, Tingting Lan, et al. · Electrochemistry Communications (2026) | TGRS Research Map | TGRS