A Significantly Higher Glucose Concentration in Plasma Collected with Glycolytic Inhibitors than in Serum: Impact of Insulin Resistance

<b>Objectives</b>: This study aimed to identify factors influencing the magnitude of the difference between plasma glucose concentration (Glu(P)) and serum glucose concentration (Glu(S)). <b>Methods</b>: A total of 333 healthy Japanese adults aged 22-29 years (212 males and 121 females) were enrolled. Plasma samples were collected using glycolytic inhibitors, whereas serum samples were obtained without glycolytic inhibitors and kept at room temperature. Glu(P) and Glu(S) were measured and compared. <b>Results</b>: The median difference between Glu(P) and Glu(S), defined as Glu(P-S), was 4 mg/dL across all participants, with no gender-related differences. A strong positive correlation was observed between Glu(P) and Glu(S). Glu(P-S) was positively correlated with body mass index, Glu(P), triglyceride-glucose index, white blood cell count, serum sodium, magnesium, and zinc levels. In contrast, Glu(P-S) was negatively correlated with Glu(S), hemoglobin A1c (HbA1c), homeostasis model assessment of beta-cell function, and high-density lipoprotein cholesterol (HDL-C). Multiple regression analysis demonstrated that HDL-C and HbA1c were independent determinants of Glu(P-S) in the overall cohort. Among females, HDL-C, triglyceride, low-density lipoprotein cholesterol, ferritin, and <i>C</i>-reactive protein independently influenced Glu(P-S), whereas no independent determinants were identified in males. <b>Conclusions</b>: Plasma glucose concentrations measured with glycolytic inhibitors were significantly higher than serum glucose concentrations measured without inhibitors at room temperature. The magnitude of Glu(P-S) appears to be associated with markers of insulin resistance, particularly HDL-C levels.

Authors

Institutions

Publication Details

Journal
Nutrients
Published
2026-03-02
DOI
https://doi.org/10.3390/nu18050813
Primary Topic
Diabetes, Cardiovascular Risks, and Lipoproteins
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Significantly Higher Glucose Concentration in Plasma Collected with Glycolytic Inhibitors than in Serum: Impact of Insulin Resistance

T Nagasawa, Mari Hashimoto, Mayumi Nishiyama, Suguru Hiramoto et al.
Nutrients
Diabetes, Cardiovascular Risks, and Lipoproteins
article

A Significantly Higher Glucose Concentration in Plasma Collected with Glycolytic Inhibitors than in Serum: Impact of Insulin Resistance

T Nagasawa, Mari Hashimoto, Mayumi Nishiyama, Suguru Hiramoto, Katsuhiko Tsunekawa, Madoka Inoue, Fumitaka Murakami, Takao Kimura, Sakura Motoki, Akihiro Yoshida
article en

Abstract

<b>Objectives</b>: This study aimed to identify factors influencing the magnitude of the difference between plasma glucose concentration (Glu(P)) and serum glucose concentration (Glu(S)). <b>Methods</b>: A total of 333 healthy Japanese adults aged 22-29 years (212 males and 121 females) were enrolled. Plasma samples were collected using glycolytic inhibitors, whereas serum samples were obtained without glycolytic inhibitors and kept at room temperature. Glu(P) and Glu(S) were measured and compared. <b>Results</b>: The median difference between Glu(P) and Glu(S), defined as Glu(P-S), was 4 mg/dL across all participants, with no gender-related differences. A strong positive correlation was observed between Glu(P) and Glu(S). Glu(P-S) was positively correlated with body mass index, Glu(P), triglyceride-glucose index, white blood cell count, serum sodium, magnesium, and zinc levels. In contrast, Glu(P-S) was negatively correlated with Glu(S), hemoglobin A1c (HbA1c), homeostasis model assessment of beta-cell function, and high-density lipoprotein cholesterol (HDL-C). Multiple regression analysis demonstrated that HDL-C and HbA1c were independent determinants of Glu(P-S) in the overall cohort. Among females, HDL-C, triglyceride, low-density lipoprotein cholesterol, ferritin, and <i>C</i>-reactive protein independently influenced Glu(P-S), whereas no independent determinants were identified in males. <b>Conclusions</b>: Plasma glucose concentrations measured with glycolytic inhibitors were significantly higher than serum glucose concentrations measured without inhibitors at room temperature. The magnitude of Glu(P-S) appears to be associated with markers of insulin resistance, particularly HDL-C levels.

NutrientsVol. 18(5)
Gunma University (JP), Ikuei Junior College (JP), Gunma University Hospital (JP)
Gender equality
Openalex Percentile: Top 37%
Diabetes, Cardiovascular Risks, and Lipoproteins
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.