CFD-Based Design Evaluation of a Packed-Bed Reactor for Enzymatic Nitrogen Recovery from Human Urine: A Comparison of Particle-Resolved and Pseudo-Homogeneous Models

This study analyzes hydrodynamics and mass transfer in a packed-bed reactor (PBR) by comparing two representations of bed geometry. The first is a pseudo-homogeneous approach using effective parameters, such as a radial porosity distribution. The second is a heterogeneous approach with resolved particles in the CAD domain. Both models simulate single-phase flow and mass transfer of urea and NH3 for an enzymatic reaction across a wide Reynolds number range 5≤Rep≤750. The pseudo-homogeneous model incorporated a detailed porosity distribution, derived from the heterogeneous model’s solids layout, which aligned well with literature, including classical correlations for radial porosity in packed beds. Additionally, hydrodynamic predictions were benchmarked against established pressure-drop correlations for confined packed beds, supporting the physical consistency of the particle-resolved framework. This non-uniform porosity informed local variations in permeability and dispersion coefficients. Velocity, pressure, and concentration fields from both approaches were compared to quantify predictive quality. Results indicate that a well-configured pseudo-homogeneous model can closely match heterogeneous model predictions, achieving similar accuracy in many flow regimes, with accumulated average relative errors below 8%. However, its performance varies with flow conditions. The optimal pseudo-homogeneous model (showing the highest predictive consistency with the particle-resolved simulations) was then used for transient simulations. These dynamic results support the preliminary sizing and conceptual design of a device for nutrient recovery from human urine for agricultural use, demonstrating the utility of simplified models for complex reactor design while acknowledging that full experimental validation under real urine-matrix conditions remains beyond the scope of the present study.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-03-02
DOI
https://doi.org/10.3390/pr14050817
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD-Based Design Evaluation of a Packed-Bed Reactor for Enzymatic Nitrogen Recovery from Human Urine: A Comparison of Particle-Resolved and Pseudo-Homogeneous Models

Alejandro Regalado-Méndez, Luis Gonzaga Alonso Zárate, Mario E. Cordero, Hugo Pérez-Pastenes et al.
Processes
Wastewater Treatment and Reuse
article

CFD-Based Design Evaluation of a Packed-Bed Reactor for Enzymatic Nitrogen Recovery from Human Urine: A Comparison of Particle-Resolved and Pseudo-Homogeneous Models

Alejandro Regalado-Méndez, Luis Gonzaga Alonso Zárate, Mario E. Cordero, Hugo Pérez-Pastenes, Sebastián Uribe, Ever Peralta-Reyes
article en

Abstract

This study analyzes hydrodynamics and mass transfer in a packed-bed reactor (PBR) by comparing two representations of bed geometry. The first is a pseudo-homogeneous approach using effective parameters, such as a radial porosity distribution. The second is a heterogeneous approach with resolved particles in the CAD domain. Both models simulate single-phase flow and mass transfer of urea and NH3 for an enzymatic reaction across a wide Reynolds number range 5≤Rep≤750. The pseudo-homogeneous model incorporated a detailed porosity distribution, derived from the heterogeneous model’s solids layout, which aligned well with literature, including classical correlations for radial porosity in packed beds. Additionally, hydrodynamic predictions were benchmarked against established pressure-drop correlations for confined packed beds, supporting the physical consistency of the particle-resolved framework. This non-uniform porosity informed local variations in permeability and dispersion coefficients. Velocity, pressure, and concentration fields from both approaches were compared to quantify predictive quality. Results indicate that a well-configured pseudo-homogeneous model can closely match heterogeneous model predictions, achieving similar accuracy in many flow regimes, with accumulated average relative errors below 8%. However, its performance varies with flow conditions. The optimal pseudo-homogeneous model (showing the highest predictive consistency with the particle-resolved simulations) was then used for transient simulations. These dynamic results support the preliminary sizing and conceptual design of a device for nutrient recovery from human urine for agricultural use, demonstrating the utility of simplified models for complex reactor design while acknowledging that full experimental validation under real urine-matrix conditions remains beyond the scope of the present study.

ProcessesVol. 14(5)
Universidad Popular Autónoma del Estado de Puebla (MX), Missouri University of Science and Technology (US), Universidad del Mar (CL), Universidad de Puebla (MX), Centro Universitario de Coatzacoalcos (MX)
Zero hunger
Openalex Percentile: Top 33%
Wastewater Treatment and Reuse
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.