Drug‐Coated Balloons in Coronary Artery Disease: Engineering, Pharmacology, and the Mechanisms Behind Angiographic Outcomes

Drug-coated balloon (DCB) angioplasty represents a unique drug-delivery paradigm in which all therapeutic efficacy depends on the first seconds of device-tissue interaction. Unlike drug-eluting stents (DES), DCBs must achieve meaningful drug transfer, penetration, and retention during a single, brief inflation. This review provides a mechanistic, bench-to-bedside framework linking drug physicochemistry, excipient chemistry, coating engineering, balloon mechanics, and tissue pharmacokinetics to angiographic and clinical outcomes. Paclitaxel-based DCBs consistently outperform sirolimus-coated platforms in early drug uptake, intracellular retention, transmural distribution, and late lumen loss. These advantages derive from paclitaxel's extreme lipophilicity, particulate deposition, and high-affinity microtubule binding, which enable durable antiproliferative activity despite modest absolute transfer. Sirolimus, by contrast, requires an engineered delivery system-crystalline matrices, PLGA micro-reservoirs, nanoparticle carriers, or pressure-driven infusion-to compensate for its lower membrane permeability and reversible intracellular binding. Integrating preclinical modeling, coating-stability studies, optical coherence tomography (OCT) remodeling signatures, randomized trials, and recent meta-analyses, this review demonstrates that DCB therapy is not a drug-class effect: technology, not drug load, determines biological behavior. Early transfer efficiency, tissue retention kinetics, depth of penetration, and platform-specific dissection response fully explain the divergent angiographic patterns observed across devices. Understanding these mechanistic principles is essential for rational device selection and for guiding the next generation of DCB technologies capable of achieving consistent and durable clinical performance.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-03-03
DOI
https://doi.org/10.1002/ccd.70542
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Drug‐Coated Balloons in Coronary Artery Disease: Engineering, Pharmacology, and the Mechanisms Behind Angiographic Outcomes

Stefano Sasso, Andrea Di Bella, Gianluca Massaro, Vincenzo Paragliola et al.
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Drug‐Coated Balloons in Coronary Artery Disease: Engineering, Pharmacology, and the Mechanisms Behind Angiographic Outcomes

Stefano Sasso, Andrea Di Bella, Gianluca Massaro, Vincenzo Paragliola, Marcello Marchetta, Lucio Granata, Giuseppe Massimo Sangiorgi, Maria Crapanzano, Giorgio Carrillo, Fiorenza Levantesi, Daniela Benedetto
article en

Abstract

Drug-coated balloon (DCB) angioplasty represents a unique drug-delivery paradigm in which all therapeutic efficacy depends on the first seconds of device-tissue interaction. Unlike drug-eluting stents (DES), DCBs must achieve meaningful drug transfer, penetration, and retention during a single, brief inflation. This review provides a mechanistic, bench-to-bedside framework linking drug physicochemistry, excipient chemistry, coating engineering, balloon mechanics, and tissue pharmacokinetics to angiographic and clinical outcomes. Paclitaxel-based DCBs consistently outperform sirolimus-coated platforms in early drug uptake, intracellular retention, transmural distribution, and late lumen loss. These advantages derive from paclitaxel's extreme lipophilicity, particulate deposition, and high-affinity microtubule binding, which enable durable antiproliferative activity despite modest absolute transfer. Sirolimus, by contrast, requires an engineered delivery system-crystalline matrices, PLGA micro-reservoirs, nanoparticle carriers, or pressure-driven infusion-to compensate for its lower membrane permeability and reversible intracellular binding. Integrating preclinical modeling, coating-stability studies, optical coherence tomography (OCT) remodeling signatures, randomized trials, and recent meta-analyses, this review demonstrates that DCB therapy is not a drug-class effect: technology, not drug load, determines biological behavior. Early transfer efficiency, tissue retention kinetics, depth of penetration, and platform-specific dissection response fully explain the divergent angiographic patterns observed across devices. Understanding these mechanistic principles is essential for rational device selection and for guiding the next generation of DCB technologies capable of achieving consistent and durable clinical performance.

Catheterization and Cardiovascular Interventions
University of Messina (IT), University of Rome Tor Vergata (IT)
Openalex Percentile: Top 35%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.