Beta-Cell Function Assessment by In-Silico Modeling Using Three Samples from an Oral Glucose Tolerance Test During Pregnancy Possibly Complicated by Gestational Diabetes

Background/Objectives: In pregnancy, beta-cell function is of interest since not only insulin resistance but also beta-cell dysfunction is common, especially when gestational diabetes mellitus (GDM) occurs. Typically, model-based beta-cell function is assessed with (at least) five-sample oral glucose tolerance test (OGTT). The aim of this study was to investigate whether the clinically common three-sample OGTT is sufficient for model-based beta-cell function assessment in pregnancy. Methods: We studied a group of pregnant women undergoing a 2 h five-sample OGTT with glucose, insulin, and C-peptide measurement at early and/or mid-pregnancy, for a total of 152 OGTTs. The five-sample OGTT was used for model-based beta-cell function assessment, yielding three beta-cell function parameters, i.e., glucose sensitivity (GSENS), potentiation factor ratio (PFR), and rate sensitivity (RSENS). GSENS, PFR, and RSENS assessment was repeated with the three-sample OGTT (at 0, 60, 120 min) and related values were compared to those from the five-sample OGTT (reference). Results: We found that, for GSENS, regression and Bland–Altman analyses showed satisfactory results (conditional and marginal R2 values: 0.56 and 0.75, p < 0.0001, and limits of agreement containing 94.2% of samples). Moreover, five-sample and three-sample OGTT GSENS versions were fully consistent in patient subgroup analyses. Results for PFR were less satisfactory but acceptable, whereas those for RSENS were not reliable. Conclusions: The three-sample OGTT is acceptable for model-based beta-cell function assessment in pregnancy, although not for all parameters. Our methodology may be used to explore the effect of time sample reduction in other in-silico models.

Authors

Institutions

Publication Details

Journal
Diabetology
Published
2026-03-03
DOI
https://doi.org/10.3390/diabetology7030048
Primary Topic
Gestational Diabetes Research and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beta-Cell Function Assessment by In-Silico Modeling Using Three Samples from an Oral Glucose Tolerance Test During Pregnancy Possibly Complicated by Gestational Diabetes

Tina Linder, Florian Heinzl, Agnese Piersanti, Andrea Tura et al.
Diabetology
Gestational Diabetes Research and Management
article

Beta-Cell Function Assessment by In-Silico Modeling Using Three Samples from an Oral Glucose Tolerance Test During Pregnancy Possibly Complicated by Gestational Diabetes

Tina Linder, Florian Heinzl, Agnese Piersanti, Andrea Tura, Christian Göbl, Micaela Morettini
article en

Abstract

Background/Objectives: In pregnancy, beta-cell function is of interest since not only insulin resistance but also beta-cell dysfunction is common, especially when gestational diabetes mellitus (GDM) occurs. Typically, model-based beta-cell function is assessed with (at least) five-sample oral glucose tolerance test (OGTT). The aim of this study was to investigate whether the clinically common three-sample OGTT is sufficient for model-based beta-cell function assessment in pregnancy. Methods: We studied a group of pregnant women undergoing a 2 h five-sample OGTT with glucose, insulin, and C-peptide measurement at early and/or mid-pregnancy, for a total of 152 OGTTs. The five-sample OGTT was used for model-based beta-cell function assessment, yielding three beta-cell function parameters, i.e., glucose sensitivity (GSENS), potentiation factor ratio (PFR), and rate sensitivity (RSENS). GSENS, PFR, and RSENS assessment was repeated with the three-sample OGTT (at 0, 60, 120 min) and related values were compared to those from the five-sample OGTT (reference). Results: We found that, for GSENS, regression and Bland–Altman analyses showed satisfactory results (conditional and marginal R2 values: 0.56 and 0.75, p < 0.0001, and limits of agreement containing 94.2% of samples). Moreover, five-sample and three-sample OGTT GSENS versions were fully consistent in patient subgroup analyses. Results for PFR were less satisfactory but acceptable, whereas those for RSENS were not reliable. Conclusions: The three-sample OGTT is acceptable for model-based beta-cell function assessment in pregnancy, although not for all parameters. Our methodology may be used to explore the effect of time sample reduction in other in-silico models.

DiabetologyVol. 7(3)
Marche Polytechnic University (IT), Neuroscience Institute (IT), Medical University of Vienna (AT)
Good health and well-being
Openalex Percentile: Top 33%
Gestational Diabetes Research and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.