Mitigation of inductive coupling effects on buried pipelines using gradient control conductors of overhead line configuration and hippopotamus optimization algorithm

By electromagnetic perturbation effect, the extra-high voltage (EHV) overhead transmission lines can cause significant induced voltages and currents on buried metallic pipelines located in the immediate vicinity. These voltages can present a source of hazard both for the structural I ntegrity of the metallic pipeline and for the safety of personnel responsible for operation and maintenance. This paper proposes the quasi-static modeling of the electromagnetic interference to which a buried metallic pipeline will be subjected nearby an extra-high voltage (EHV) overhead transmission line, under steady-state operating conditions of the power electrical grid. Using the electrical network analysis method to evaluate the induced voltage levels and its effects on the buried pipeline; also, to propose a mitigation strategy if necessary. The results obtained show that the values of the AC induced voltage on the buried pipeline are significant and exceed the limits defined by the international NACE standard. They can cause a risk of electrocution for intervention personnel and accelerate the process of metal corrosion. Therefore, the gradient control mitigation technique of the conductors and their optimal geometric arrangement of EHV transmission line using Hippopotamus Optimization (HO) algorithm were proposed to reduce AC induced voltages within the permissible safety limits, according to the requirements of the NACE Standard. Finally, it should be noted that the implementation of these mitigation approaches have led to remarkable results in eliminating potential risks.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-03
DOI
https://doi.org/10.1038/s41598-026-40852-5
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation of inductive coupling effects on buried pipelines using gradient control conductors of overhead line configuration and hippopotamus optimization algorithm

Ragab Abdelaziz El-Sehiemy, Kelthoum Hachani, Bachir Bentouati, Sid Ahmed Bessedik et al.
Scientific Reports
Lightning and Electromagnetic Phenomena
article

Mitigation of inductive coupling effects on buried pipelines using gradient control conductors of overhead line configuration and hippopotamus optimization algorithm

Ragab Abdelaziz El-Sehiemy, Kelthoum Hachani, Bachir Bentouati, Sid Ahmed Bessedik, Djekidel Rabah
article en

Abstract

By electromagnetic perturbation effect, the extra-high voltage (EHV) overhead transmission lines can cause significant induced voltages and currents on buried metallic pipelines located in the immediate vicinity. These voltages can present a source of hazard both for the structural I ntegrity of the metallic pipeline and for the safety of personnel responsible for operation and maintenance. This paper proposes the quasi-static modeling of the electromagnetic interference to which a buried metallic pipeline will be subjected nearby an extra-high voltage (EHV) overhead transmission line, under steady-state operating conditions of the power electrical grid. Using the electrical network analysis method to evaluate the induced voltage levels and its effects on the buried pipeline; also, to propose a mitigation strategy if necessary. The results obtained show that the values of the AC induced voltage on the buried pipeline are significant and exceed the limits defined by the international NACE standard. They can cause a risk of electrocution for intervention personnel and accelerate the process of metal corrosion. Therefore, the gradient control mitigation technique of the conductors and their optimal geometric arrangement of EHV transmission line using Hippopotamus Optimization (HO) algorithm were proposed to reduce AC induced voltages within the permissible safety limits, according to the requirements of the NACE Standard. Finally, it should be noted that the implementation of these mitigation approaches have led to remarkable results in eliminating potential risks.

Scientific ReportsVol. 16(1)
Kafrelsheikh University (EG), Amar Telidji University of Laghouat (DZ), Széchenyi István University (HU)
Széchenyi István Egyetem
Openalex Percentile: Top 37%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.