Research and Development of Intelligent Control Systems for High-Frequency Ozone Generators

This paper presents the development and investigation of an intelligent control system for a high-frequency ozone generator integrated into an IoT-based and telecommunication environment. A cyber-physical nonlinear mathematical model combining the electrical, thermal, gas-dynamic, and chemical subsystems of the ozone generation process is proposed. The model was implemented in discrete-time form and experimentally validated using the corona–discharge-based high-frequency ozonator ETRO-02. The deviation between simulation and experimental results did not exceed 5.3% for settling time, 6.7% for overshoot, 1.6% for steady-state ozone concentration, and 0.9% for gas temperature, confirming the adequacy of the proposed model. Based on this model, a hierarchical two-level intelligent control architecture is synthesized, consisting of a fast local control loop with a cycle time of 1–5 ms and a supervisory monitoring layer. The proposed adaptive state-feedback control law with online gain adjustment ensures stable real-time operation under nonlinear dynamics, ±20% parameter variations, network delays of 1–10 ms, and packet loss probabilities of up to 5%. As a result, the settling time is reduced from 420 ms to 160 ms, the overshoot from 12.5% to 3.1%, and the steady-state error from 6.5% to 1.6%, while the specific energy consumption decreases from 11.8 to 6.2 Wh/m3. The obtained results demonstrate that the integration of a cyber-physical model with a millisecond-level intelligent control system significantly improves the dynamic performance, robustness, and energy efficiency of high-frequency ozone generators compared to classical control and monitoring-oriented IoT systems. Unlike cloud-centric IoT monitoring architectures that operate at second-level update cycles, the proposed system closes the control loop locally at the millisecond scale, enabling stabilization of fast nonlinear electro-plasma dynamics. The results demonstrate that edge-intelligent adaptive control significantly enhances both dynamic performance and energy efficiency, confirming the feasibility of millisecond-level cyber-physical regulation for industrial ozone generation systems.

Authors

Institutions

Publication Details

Journal
Journal of Sensor and Actuator Networks
Published
2026-03-03
DOI
https://doi.org/10.3390/jsan15020026
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and Development of Intelligent Control Systems for High-Frequency Ozone Generators

Maxat Mamadiyarov, Сейдулла Abdullayev, Нуржигит Смайлов, Аскар Абдыкадыров et al.
Journal of Sensor and Actuator Networks
Aerosol Filtration and Electrostatic Precipitation
article

Research and Development of Intelligent Control Systems for High-Frequency Ozone Generators

Maxat Mamadiyarov, Сейдулла Abdullayev, Нуржигит Смайлов, Аскар Абдыкадыров, Dina Ermanova, Nurlan Kystaubayev
article en

Abstract

This paper presents the development and investigation of an intelligent control system for a high-frequency ozone generator integrated into an IoT-based and telecommunication environment. A cyber-physical nonlinear mathematical model combining the electrical, thermal, gas-dynamic, and chemical subsystems of the ozone generation process is proposed. The model was implemented in discrete-time form and experimentally validated using the corona–discharge-based high-frequency ozonator ETRO-02. The deviation between simulation and experimental results did not exceed 5.3% for settling time, 6.7% for overshoot, 1.6% for steady-state ozone concentration, and 0.9% for gas temperature, confirming the adequacy of the proposed model. Based on this model, a hierarchical two-level intelligent control architecture is synthesized, consisting of a fast local control loop with a cycle time of 1–5 ms and a supervisory monitoring layer. The proposed adaptive state-feedback control law with online gain adjustment ensures stable real-time operation under nonlinear dynamics, ±20% parameter variations, network delays of 1–10 ms, and packet loss probabilities of up to 5%. As a result, the settling time is reduced from 420 ms to 160 ms, the overshoot from 12.5% to 3.1%, and the steady-state error from 6.5% to 1.6%, while the specific energy consumption decreases from 11.8 to 6.2 Wh/m3. The obtained results demonstrate that the integration of a cyber-physical model with a millisecond-level intelligent control system significantly improves the dynamic performance, robustness, and energy efficiency of high-frequency ozone generators compared to classical control and monitoring-oriented IoT systems. Unlike cloud-centric IoT monitoring architectures that operate at second-level update cycles, the proposed system closes the control loop locally at the millisecond scale, enabling stabilization of fast nonlinear electro-plasma dynamics. The results demonstrate that edge-intelligent adaptive control significantly enhances both dynamic performance and energy efficiency, confirming the feasibility of millisecond-level cyber-physical regulation for industrial ozone generation systems.

Journal of Sensor and Actuator NetworksVol. 15(2)
Satbayev University (KZ), Kazakh Academy of Transport and Communications named after M.Tynyshpaev (KZ), Caspian University (KZ)
Affordable and clean energy
Openalex Percentile: Top 38%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.