Full-scale room fire of Li-ion battery modules undergoing thermal runaway

The integration of high-energy lithium-ion batteries (LIBs) as energy storage solutions is increasing in the building sector (e.g., residential, schools, offices, commercial and industrial buildings). This increases the fire load, raising fire safety concerns, including characteristic fire behaviour, increased fire intensity, faster fire growth, prolonged burning duration, fire spread and flashover risk. Full-scale fire experiments with NMC battery modules of nominal 6600 Wh were conducted in an ISO 9705 compartment. The emphasis of the work was to analyse the fire characteristics within the room from the beginning of thermal runaway in a set of individual cells and continuous cell-to-cell thermal propagation in a single module. The results revealed that simultaneous cells in thermal runaway within a module intensified heat release into the room. The fire development differed from fires in common technical rooms, exhibiting flash fire, ultra-fast fire growth, intense thermal feedback and multiple heat release rate peaks. The experimental findings provide critical data to support risk assessments of battery energy storage systems. Currently, the lack of guidelines on fire safety requirements for battery rooms limits the ability to design rooms with appropriate active and passive fire safety measures. Future research should further explore fire spread between modules and the effectiveness of active and passive fire protection measures in confined compartments. • A controlled propane burner heating method is presented to trigger thermal runaway in a battery module. • A case of gas release under thermal runaway conditions with delayed gas ignition was observed. • Simultaneous thermal runaway of multiple cells increased both the temperature and the heat release rate within the room. • The fire was self-sustained due to continuous cell-to-cell propagation. • The fire development phases within a compartment are highlighted. • The growth rate is comparable to the hydrocarbon fire curve during its fully developed stage.

Authors

Institutions

Publication Details

Journal
Fire Safety Journal
Published
2026-03-04
DOI
https://doi.org/10.1016/j.firesaf.2026.104680
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-scale room fire of Li-ion battery modules undergoing thermal runaway

Brynhild Garberg Olsø, Christoph Meraner, Anne Steen‐Hansen, Cristina Sanfeliu Meliá
Fire Safety Journal
Advanced Battery Technologies Research
article

Full-scale room fire of Li-ion battery modules undergoing thermal runaway

Brynhild Garberg Olsø, Christoph Meraner, Anne Steen‐Hansen, Cristina Sanfeliu Meliá
article en

Abstract

The integration of high-energy lithium-ion batteries (LIBs) as energy storage solutions is increasing in the building sector (e.g., residential, schools, offices, commercial and industrial buildings). This increases the fire load, raising fire safety concerns, including characteristic fire behaviour, increased fire intensity, faster fire growth, prolonged burning duration, fire spread and flashover risk. Full-scale fire experiments with NMC battery modules of nominal 6600 Wh were conducted in an ISO 9705 compartment. The emphasis of the work was to analyse the fire characteristics within the room from the beginning of thermal runaway in a set of individual cells and continuous cell-to-cell thermal propagation in a single module. The results revealed that simultaneous cells in thermal runaway within a module intensified heat release into the room. The fire development differed from fires in common technical rooms, exhibiting flash fire, ultra-fast fire growth, intense thermal feedback and multiple heat release rate peaks. The experimental findings provide critical data to support risk assessments of battery energy storage systems. Currently, the lack of guidelines on fire safety requirements for battery rooms limits the ability to design rooms with appropriate active and passive fire safety measures. Future research should further explore fire spread between modules and the effectiveness of active and passive fire protection measures in confined compartments. • A controlled propane burner heating method is presented to trigger thermal runaway in a battery module. • A case of gas release under thermal runaway conditions with delayed gas ignition was observed. • Simultaneous thermal runaway of multiple cells increased both the temperature and the heat release rate within the room. • The fire was self-sustained due to continuous cell-to-cell propagation. • The fire development phases within a compartment are highlighted. • The growth rate is comparable to the hydrocarbon fire curve during its fully developed stage.

Fire Safety JournalVol. 161
SINTEF (NO), Norwegian University of Science and Technology (NO), Tine (Norway) (NO)
Affordable and clean energy
Openalex Percentile: Top 39%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.