Proof-of-concept thermoelectrically cooled sow-cooling mat

Heat stress reduces the welfare and performance of late-gestation and lactating sows as well as the performance of their litters. Current cooling methods have shortcomings in alleviating sow heat stress. An innovative, stand-alone, thermoelectrically cooled sow-cooling mat (SCM) that does not require an external cool water source was designed, fabricated, and tested. Water circulating beneath the aluminum tread plate to remove the sow’s heat, was cooled in a heat exchanger comprising Peltier modules, heat sinks, and fans. In two farrowing room trials comparing one sow with an SCM to a control sow with no mat, the SCM’s gross cooling capacities in Trials 1 (late-summer) and 2 (mid-summer) were 395 W and 366 W, while coefficient of performance (COP) values were 3.6 and 3.2, respectively. While lack of replicates precluded drawing conclusions regarding the SCM’s impact on sow and litter performance, some performance metrics (e.g., sow weight change (Trial 2), feed intake (Trial 2), and mean final weaned piglet weight were positive. However, the SCM’s impact on sow welfare was unclear. In an environmental chamber, with two 85-W heating pads, mat center temperatures were reduced by 5 °C and 11.7 °C in Tests 1 (baseline scenario) and 2 (bottom insulated), respectively. Final cooling capacities in Tests 1 and 2 were 146 W and 161 W, respectively, while corresponding COP values were 1.3 and 1.5. The SCM’s impact on sow and litter welfare and performance should be evaluated in a larger replicated study.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-03
DOI
https://doi.org/10.1038/s41598-026-42237-0
Primary Topic
Animal Behavior and Welfare Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proof-of-concept thermoelectrically cooled sow-cooling mat

M. T. Knauer, J. Pan, S. M. Leonard, S. B. Shah et al.
Scientific Reports
Animal Behavior and Welfare Studies
article

Proof-of-concept thermoelectrically cooled sow-cooling mat

M. T. Knauer, J. Pan, S. M. Leonard, S. B. Shah, A. V. Saveliev, J. O. Evans
article en

Abstract

Heat stress reduces the welfare and performance of late-gestation and lactating sows as well as the performance of their litters. Current cooling methods have shortcomings in alleviating sow heat stress. An innovative, stand-alone, thermoelectrically cooled sow-cooling mat (SCM) that does not require an external cool water source was designed, fabricated, and tested. Water circulating beneath the aluminum tread plate to remove the sow’s heat, was cooled in a heat exchanger comprising Peltier modules, heat sinks, and fans. In two farrowing room trials comparing one sow with an SCM to a control sow with no mat, the SCM’s gross cooling capacities in Trials 1 (late-summer) and 2 (mid-summer) were 395 W and 366 W, while coefficient of performance (COP) values were 3.6 and 3.2, respectively. While lack of replicates precluded drawing conclusions regarding the SCM’s impact on sow and litter performance, some performance metrics (e.g., sow weight change (Trial 2), feed intake (Trial 2), and mean final weaned piglet weight were positive. However, the SCM’s impact on sow welfare was unclear. In an environmental chamber, with two 85-W heating pads, mat center temperatures were reduced by 5 °C and 11.7 °C in Tests 1 (baseline scenario) and 2 (bottom insulated), respectively. Final cooling capacities in Tests 1 and 2 were 146 W and 161 W, respectively, while corresponding COP values were 1.3 and 1.5. The SCM’s impact on sow and litter welfare and performance should be evaluated in a larger replicated study.

Scientific Reports
North Carolina State University (US), Huangshan University (CN)
Openalex Percentile: Top 35%
Animal Behavior and Welfare Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proof-of-concept thermoelectrically cooled sow-cooling mat — M. T. Knauer, J. Pan, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS